association between obstetric conjugate diameter measured by transabdominal ultrasonography during pregnancy and the type of delivery

نویسندگان

mohammad hossein daghighi department of radiology, radiotherapy and nuclear medicine, tabriz university of medical sciences, tabriz, iran; department of radiology, radiotherapy and nuclear medicine, tabriz university of medical sciences, tabriz, iran. tel: +98-4113346911 fax: +984113346911

masoud poureisa neurosciences research center (nsrc), tabriz university of medical sciences, tabriz, iran

mahnaz ranjkesh department of radiology, radiotherapy and nuclear medicine, tabriz university of medical sciences, tabriz, iran

چکیده

objectives we aimed to evaluate the association between obstetric conjugate diameter (ocd) measured by ultrasonography and the type of delivery, vaginally (v) or by cesarean (c) section. conclusion the us measurement of ocd might be an accurate method that almost always remains constant during late pregnancy; it is easy to measure and might be confidentially employed for predicting c-section, but needs more precise studies to be used widely. results the mean ocd of both sonographies in groups v and c was 125.51± 8.35 mm (105-144.5) and 112.99 ± 8.53 mm (96-134.5), respectively, which was significantly lower in group c (p<0.001). the values of ocd between the first and second measurements were not different significantly (p=0.065). c-section was indicated in 65 (32.5%) mothers. the optimal cut-off point for the ocd in the prediction of vaginal delivery was ≥ 119.75 mm, with a sensitivity and specificity of 80% and 78.5%, respectively. patients and methods pelvimetry was performed in 200 primigravid women for fetal cephalic presentation. the ocd was measured twice by transabdominal ultrasonography during 25-30 weeks and 30-35 weeks of pregnancy. background normal morphological features of the maternal pelvis are an important prerequisite to vaginal delivery.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Association Between Obstetric Conjugate Diameter Measured by Transabdominal Ultrasonography During Pregnancy and the Type of Delivery

BACKGROUND Normal morphological features of the maternal pelvis are an important prerequisite to vaginal delivery. OBJECTIVES We aimed to evaluate the association between obstetric conjugate diameter (OCD) measured by ultrasonography and the type of delivery, vaginally (V) or by cesarean (C) section. PATIENTS AND METHODS Pelvimetry was performed in 200 primigravid women for fetal cephalic p...

متن کامل

Transvaginal and transabdominal ultrasonography of the uterine cervix during pregnancy.

Transvaginal and transabdominal ultrasound evaluation of the uterine cervix were compared in a study of 186 pregnant women. An empty bladder made transabdominal ultrasound measurement of the cervix more difficult, while bladder filling resulted in significant lengthening of the transabdominal cervical measurement. In contrast, transvaginal ultrasound cervical measurement was possible in all but...

متن کامل

Association between depression and delivery type

Introduction: Depression during pregnancy disturbs daily activities, acceptance of new roles, pregnant woman&acute;s life responsibilities, and pregnancy consequences. The goal of this study is to investigate the association between depression during pregnancy and type of delivery and some personal characteristics. Methods: This is a descriptive analytical study in which the data were collected...

متن کامل

examining the relationship between fear of negative evaluation and communication strategies by iranian efl learners

the purpose of the present study was to investigate the relationship between fear of negative evaluation (fne) and communication strategies (css) among iranian efl learners. it was aimed to examine the differences in the use of communication strategies between speakers with high or low degree of fear of negative evaluation. the current study was a case study consisting of 10 english learners at...

The relationship between inferior vena cava diameter measured by bedside ultrasonography and central venous pressure value

OBJECTIVE We aimed to present inferior vena cava (IVC) diameter as a guiding method for detection of relationship between IVC diameter measured noninvasively with the help of ultrasonography (USG) and central venous pressure (CVP) and evaluation of patient's intravascular volume status. METHODS Patients over the age of 18, to whom a central venous catheter was inserted to their subclavian vei...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiology

جلد ۱۰، شماره ۳، صفحات ۱۸۵-۱۸۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023