automatic bolus tracking versus fixed time-delay technique in biphasic multidetector computed tomography of the abdomen
نویسندگان
چکیده
conclusions the automatic bolus-tracking method, results in higher contrast enhancement of the aorta and spleen at the portal phase, but has no effect on liver enhancement. however, bolus tracking is associated with reduced variability for liver enhancement among different patients. results forty-eight patients (23 male, 25 female, mean age=56.4±13.5 years) were included. the contrast enhancement of the aorta, liver, and spleen at the arterial phase was similar between the two groups (p > 0.05). regarding the portal phase, the aorta and spleen were more enhanced in the bolus-tracking group (p<0.001). the bolus tracking provided more homogeneous contrast enhancement among different patients than the fixed time-delay technique in the liver at portal phase, but not at the arterial phase. patients and methods adult patients referred for spiral ct of the abdomen were randomized into two groups; in group 1, the arterial and portal phases of spiral scans were started 25 s and 55 s after the start of contrast material administration; in group 2, using the automatic bolus tracking software, repetitive monitoring scans were performed within the lumen of the descending aorta as the region of interest with the threshold of starting the diagnostic scans as 60 hu. the contrast enhancement of the aorta, liver, and spleen were compared between the groups. background bolus tracking can individualize time delay for the start of scans in spiral computed tomography (ct). objectives we compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector ct of abdomen.
منابع مشابه
Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen
BACKGROUND Bolus tracking can individualize time delay for the start of scans in spiral computed tomography (CT). OBJECTIVES We compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector CT of abdomen. PATIENTS AND METHODS Adult patients referred for spiral CT of the abdomen were randomized into two groups; in group 1, the ...
متن کاملsplit-bolus multidetector-row computed tomography technique for characterization of focal liver lesions in oncologic patients
conclusion the designed split-bolus mdct technique can be proposed alternatively to triphasic mdct and in a single-pass to pvp in the initial staging and in the follow-up respectively in oncologic patients. patients and methods we retrospectively analyzed the follow-up split-bolus 64-detector row ct protocol in 36 oncologic patients to characterize focal liver lesions. the split-bolus mdct prot...
متن کاملSplit-bolus versus triphasic multidetector-row computed tomography technique in the diagnosis of hepatic focal nodular hyperplasia: a case report
INTRODUCTION Computed tomography and magnetic resonance imaging are able to demonstrate and to diagnose hepatic focal nodular hyperplasia when a typical pattern of a well-circumscribed lesion with a central scar is present.Our aim is to propose the split-bolus multidetector-row computed tomography technique as an alternative to the conventional triphasic technique in the detection and character...
متن کاملSplit-Bolus Multidetector-Row Computed Tomography Technique for Characterization of Focal Liver Lesions in Oncologic Patients
BACKGROUND In oncologic patients, the liver is the most common target for metastases. An accurate detection and characterization of focal liver lesions in patients with known primary extrahepatic malignancy are essential to define management and prognosis. OBJECTIVES To assess the diagnostic accuracy of the split-bolus multidetector-row computed tomography (MDCT) protocol in the characterizat...
متن کاملEstablishment of optimal scan delay for multi-phase computed tomography using bolus-tracking technique in canine pancreas
To establish a protocol for a multi-phase computed tomography (CT) of the canine pancreas using the bolus-tracking technique, dynamic scan and multi-phase CT were performed in six normal beagle dogs. The dynamic scan was performed for 60 sec at 1-sec intervals after the injection (4 ml/sec) of a contrast medium, and intervals from aortic enhancement appearance to aortic, pancreatic parenchymal ...
متن کاملMultidetector computed tomography of chest trauma: indications, technique and interpretation
BACKGROUND Chest traumas are a significant cause of mortality and morbidity, especially in the younger population.Methods Diagnostic imaging plays a key role in their management. Multidetector computed tomography (MDCT) is the most important imaging method in this field. Its advantages include especially high speed and high geometric resolution in any plane.Results The method allows us to view ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiologyجلد ۱۱، شماره ۱، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023