evaluation of enteroneovesical fistula by 64-detector ct enterography: a case report

نویسندگان

oktay algin department of radiology, ataturk training and research hospital, ankara, turkey; department of radiology, ataturk training and research hospital, ankara, turkey. tel: +90-3122912525

melike rusen metin department of radiology, ataturk training and research hospital, ankara, turkey

mustafa karaoglanoglu department of radiology, ataturk training and research hospital, ankara, turkey

چکیده

enterovesical fistula is an abnormal communication between the bladder and the intestine. the accurate localization of leakage is important for accurate treatment planning. some imaging techniques can not demonstrate the fistula; therefore, choosing the appropriate imaging technique is necessary. ct enterography (cte) is a new technique for evaluation of the small bowel and the entire abdomen. cte examination with multi-detector ct (mdct) enables us to get excellent quality reformatted images with high spatial resolution. we report a patient with neobladder and enteroneovesical fistula. we showed the exact location of the fistula and its’ association with the bowels and neobladder by cte. the aim of this report is to show that cte can be a new and effective modality in the detection of enteroneovesical fistulas and to discuss the efficacy of cte in the detection and evaluation of enterovesical fistula referring to the literature. in conclusion, cte may be a useful, sensitive, effective, and non-invasive technique for the evaluation of enteroneovesical fistula, leakage from the anastomose sides, and other extraintestinal complications such as urinary tract obstruction or abscess formation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Enteroneovesical Fistula by 64-Detector CT Enterography: A Case Report

Enterovesical fistula is an abnormal communication between the bladder and the intestine. The accurate localization of leakage is important for accurate treatment planning. Some imaging techniques can not demonstrate the fistula; therefore, choosing the appropriate imaging technique is necessary. CT enterography (CTE) is a new technique for evaluation of the small bowel and the entire abdomen. ...

متن کامل

desmoid tumor associated with familial adenomatous polyposis: evaluation with 64-detector ct enterography

abstract desmoid tumors (dts) are benign tumors which are not seen very often, and most of the radiologists and clinicians do not know the characteristics of them very well. correct and early diagnosis of dts is important for decreasing mortality and morbidity. computed tomography enterography (cte) is a new modality for small bowel imaging which combines the improved spatial and temporal resol...

متن کامل

Desmoid Tumor Associated With Familial Adenomatous Polyposis: Evaluation With 64-Detector CT Enterography

Desmoid tumors (DTs) are benign tumors which are not seen very often, and most of the radiologists and clinicians do not know the characteristics of them very well. Correct and early diagnosis of DTs is important for decreasing mortality and morbidity. Computed tomography enterography (CTE) is a new modality for small bowel imaging which combines the improved spatial and temporal resolution of ...

متن کامل

Spinal dural arteriovenous fistula : a case report

Background: Spinal dural AVF is the most common type of spinal vascular malformation. However, presenting symptoms differ according to site of spinal involvement. This study described a case of arteriovenous malformation with paraparesis and incontinence. Case Presentation: Diagnosis of patient was confirmed by clinical and imaging examination using magnetic resonance image and ruling out ot...

متن کامل

Obscure gastrointestinal bleeding: evaluation with 64-section multiphase CT enterography--initial experience.

This retrospective HIPAA-compliant study was approved by the institutional review board and institutional conflict of interest committee. Patients gave informed consent for use of medical records. The purpose of the study was to retrospectively evaluate the findings depicted at computed tomographic (CT) enterography performed with a 64-section CT system and by using neutral enteric contrast mat...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiology

جلد ۱۲، شماره ۲، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023