evaluating the linear model of dielectric constant-electrical conductivity for estimation of soil solution electrical conductivity with tdr
نویسندگان
چکیده
abstract time domain reflectometry (tdr) is a widely used method for measuring the dielectric constant (ka) and bulk electrical conductivity (σa) in soils. the tdr-measured σa and ka can be used to calculate the soil solution electrical conductivity, (σp). a theoretical model describing a linear relationship between bulk electrical conductivity, σa, and dielectric constant, ka, in moist soil was already presented. by using this linear relationship, the pore water electrical conductivity, σp, can be estimated in a wide range of soil types without soil-specific calibration. the objective of this study was to evaluate the linear model presented previously for tdr. the previous study was on light texture soils but in this study we used clay, clay loam, loam, silty clay and silty clay loam textures. the results showed that the linear model performed well for light texture soils but not for heavy textures. such poor result for heavy texture is mainly due to this fact that dielectric constant pore water was lower than 80 which was proposed as default by model. this study showed that for heavy texture soils dielectric constant of pore water is smaller than light textured soils.
منابع مشابه
Evaluating the linear dielectric constant-electrical conductivity model using time-domain reflectometry
Recently, Hilhorst (2000) presented a theoretical model describing a linear relationship between bulk electrical conductivity, o0, and dielectric constant, K„, in moist soil. Hilhorst (2000) found that using this linear relationship, measurements of the pore water electrical conductivity, ap, can be made in a wide range of soil types without soil-specific calibrations. If accurate measurements ...
متن کاملELECTRICAL CONDUCTIVITY OF LOW DIELECTRIC CONSTANT LIQUIDS by
This experimental investigation was carried out in order to determine the electrical characteristics of several hydrocarbons of low dielectric constant. All measurements of the conduc ivity were below 1 picomho/m (u.10A/V-m 10-14 ohm'lcml). This category ncludes most petroleum products, petroleum distillates made conductive by adding anti-static additives, and liquified gases. Of particular int...
متن کاملA TDR-Based Soil Moisture Monitoring System with Simultaneous Measurement of Soil Temperature and Electrical Conductivity
Elements of design and a field application of a TDR-based soil moisture and electrical conductivity monitoring system are described with detailed presentation of the time delay units with a resolution of 10 ps. Other issues discussed include the temperature correction of the applied time delay units, battery supply characteristics and the measurement results from one of the installed ground mea...
متن کاملElectrical conductivity of CuO nanofluids
An empirical electrical conductivity assessment of nanofluids comprising CuO nanoparticles water-based in different concentrations, particles size and various temperatures of nanofluids has been carried out in this paper. These experimentations have been done in deionized water with nanoparticles sizes such as 89, 95, 100 and 112 nm and concentrations of 0.12 g/l, 0.14 g/l, 0.16 g/l and 0.18 g/...
متن کاملestimation of apparent soil electrical conductivity using direct contact method
abstract wenner direct contact method is a method of estimating apparent electrical conductivity (eca) of agricultural soils in situ. this method can be affected by factors such as quality of electrodes in contact with soil, type of employed electric current, moisture content, clay content and compaction of soil. in this research, the effect of electrode type (rod and plate) and electric curren...
متن کاملElectrical conductivity of CuO nanofluids
An empirical electrical conductivity assessment of nanofluids comprising CuO nanoparticles water-based in different concentrations, particles size and various temperatures of nanofluids has been carried out in this paper. These experimentations have been done in deionized water with nanoparticles sizes such as 89, 95, 100 and 112 nm and concentrations of 0.12 g/l, 0.14 g/l, 0.16 g/l and 0.18 g/...