diagnostic accuracy of dual-source computerized tomography coronary angiography in symptomatic patients presenting to a referral cardiovascular center during daily clinical practice
نویسندگان
چکیده
conclusion our results indicate that dsct coronary angiography provides high diagnostic accuracy for the evaluation of cad patients during daily routine practice of a referral cardiovascular setting. background there are numerous studies that address the diagnostic value of dual-source computed tomography (dsct) as an alternative to conventional coronary angiography (cca). however, the benefit of application of dsct in a real world clinical setting should be evaluated. objectives to determine the diagnostic accuracy of dsct technique compared with cca as the gold standard method in detection of coronary artery stenosis among symptomatic patients who are presented to a referral cardiovascular center during daily clinical practice. patients and methods evaluating the medical records of a tertiary care referral cardiovascular center, 47 patients who had undergone dsct and cca, and also met the inclusion and exclusion criteria of the study were selected. sensitivity, specificity, positive predictive value (ppv), negative predictive value (npv), and likelihood ratios (lrs) of the dsct imaging technique were calculated. results in total, 97.8% of the segments (628/642) could be visualized with diagnostic image quality via dsct coronary angiography. the mean heart rate during dsct was 69.2 ± 12.2 bpm (range: 39 - 83 bpm), and the mean agatston score was 507.7 ± 590.5 (range: 0 - 2328). per segment analysis of the findings revealed that the sensitivity, specificity, ppv, npv, positive lr (plr) and negative lr (nlr) of dsct technique for evaluation of patients with coronary artery disease were 93.7%, 96.8%, 92.7%, 97.2%, 29.4, and 0.066, respectively. also per vessel, analysis of the findings showed a sensitivity of 97.1%, a specificity of 94.0%, ppv of 95.3%, npv of 96.3%, plr of 16.1, and nlr of 0.030.
منابع مشابه
Diagnostic Accuracy of Dual-Source Computerized Tomography Coronary Angiography in Symptomatic Patients Presenting to a Referral Cardiovascular Center During Daily Clinical Practice
BACKGROUND There are numerous studies that address the diagnostic value of dual-source computed tomography (DSCT) as an alternative to conventional coronary angiography (CCA). However, the benefit of application of DSCT in a real world clinical setting should be evaluated. OBJECTIVES To determine the diagnostic accuracy of DSCT technique compared with CCA as the gold standard method in detect...
متن کاملDiagnostic accuracy of computed tomography angiography in patients after bypass grafting: comparison with invasive coronary angiography.
OBJECTIVES We sought to evaluate the contribution of noninvasive dual-source computed tomography angiography (CTA) in the comprehensive assessment of symptomatic patients after coronary artery bypass grafting (CABG). BACKGROUND Assessment of bypass grafts and distal runoffs by invasive coronary angiography is cumbersome and often requires extra procedure time, contrast load, and radiation exp...
متن کاملAccuracy of dual-source computed tomography coronary angiography: evaluation with a standardised protocol for cardiac surgeons.
BACKGROUND This study assesses the accuracy of the new dual-source computed tomography (DSCT) for detection of coronary artery disease (CAD) compared with invasive coronary angiography (ICA) with a specifically designed data presentation protocol for cardiac surgeons. METHODS Forty patients (30 males/10 females) underwent ICA and DSCT. Best-quality images were prepared by radiologists. Evalua...
متن کاملClinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...
متن کاملDiagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease.
OBJECTIVES The aim of the present study was to evaluate the diagnostic accuracy in detecting high-grade coronary stenoses in patients with known coronary artery disease (CAD) using multidetector computed tomography (MDCT). BACKGROUND The MDCT systems with electrocardiographic (ECG)-gating permit visualization of the coronary arteries. However, severe calcifications and higher heart rates are ...
متن کاملEffect of age and plaque morphology on diagnostic accuracy of dual source multidetector computed tomography coronary angiography
BACKGROUND Multidetector computed tomography (MDCT) coronary angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. The purpose of this study is to investigate the effect of age and coronary plaque calcification on diagnostic accuracy of MDCT. METHODS The patients were examined...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiologyجلد ۱۳، شماره ۲، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023