multi-objective semi-active base isolation system
نویسندگان
چکیده
semi-active base isolation system has been proposed mainly to mitigate the base drift of isolated structures while in most cases, its application causes the maximum acceleration of superstructure to be increased. in this paper, designing optimal semi-active base isolation system composed of linear base isolation system with low damping and magneto-rheological (mr) damper has been studied for controlling superstructure acceleration and base drift separately and simultaneously. a multi-objective optimization problem has been defined for optimal design of semi-active base isolation system which considers a linear combination of maximum acceleration and base drift as objective function where genetic algorithm (ga) has been used to solve the optimization problem. h2/linear quadratic gaussian (lqg) and clipped-optimal control algorithms have been used to determine the desired control force and the voltage of mr damper in each time step. for numerical simulation, a four-story base isolated shear frame has been considered and for different values of weighting parameter in objective function, optimal semi-active base isolation system has been designed under various design earthquakes. the results show that by using base isolation system and supplemental mr damper, the superstructure acceleration and base drift can be suppressed significantly. also, it has been concluded that by selecting proper values for maximum acceleration and base drift related weighting parameters in objective function, it is possible to mitigate the maximum acceleration and base drift simultaneously. furthermore, semi-active control system has worked successfully under testing earthquakes regarding design criteria.
منابع مشابه
MULTI-OBJECTIVE SEMI-ACTIVE BASE ISOLATION SYSTEM
Semi-active base isolation system has been proposed mainly to mitigate the base drift of isolated structures while in most cases, its application causes the maximum acceleration of superstructure to be increased. In this paper, designing optimal semi-active base isolation system composed of linear base isolation system with low damping and magneto-rheological (MR) damper has been studied for co...
متن کاملSemi-active Base isolation System for Buildings using MR Dampers
Due to limitations on the use of passive base isolation systems which show poor performance in near field seismic excitations or active systems which require high external power, as stand alone control devices for a range of seismic excitations, a hybrid control system that mitigates the limitations of either passive or active control systems is preferred. The present study examines the use of ...
متن کاملHybrid Controlled Base-isolation System with Semi-active Magnetorheological Damper and Rolling Pendulum System
A series of large-scale experimental tests is conducted on a mass equipped with a hybrid controlled base-isolation system that consists of rolling pendulum system (RPS) and a 20 kN magnetorheological (MR) damper. The 12-ton mass and its hybrid isolation system are subjected to various intensities of nearand far-fault earthquakes on a large shake table. Fuzzy controllers use feedback from displa...
متن کاملMERBIS - A Multi-Objective Evolutionary Rule Base Induction System
Classifier induction is a specific data-mining task that is part of the knowledge discovery process. Its objectives are to extract accurate, comprehensible and interesting knowledge. However, most classifier induction approaches focus only on one of these objectives. This paper introduces a Multi-Objective Evolutionary Rule Base Induction System (MERBIS) that is capable of optimising both, accu...
متن کاملMulti-objective Optimization of Semi-active Control of Seismically Exited Buildings Using Variable Damper and Genetic Algorithms
Semi-active fluid viscous dampers as a subset of control systems have shown their ability to reduce seismic responses of tall buildings. In this paper, multi-objective optimization of the performance of this group of dampers in reducing the seismic responses of buildings is studied using multi-objective genetic algorithms. For numerical example, two 7 and 18 stories buildings are chosen and mod...
متن کاملApplication of Active Base Isolation Control
The structural control can provide the potential protection through passive and active control techniques. Structures with base isolations have been successfully implemented and proven effective in the vibration mitigation. To enhance the functionality of base isolations, a hybrid control system can be considered using a combination with active control devices. This research applies the hybrid ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
international journal of optimaization in civil engineeringجلد ۷، شماره ۳، صفحات ۳۱۹-۳۳۸
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023