mathematical method and thermodynamic approaches to design multi-component refrigeration used in cryogenic process part i: optimal operating conditions

نویسندگان

mostafa mafi

department of mechanical engineering, imam khomeini international university, qazvin, iran majid amidpour

faculty of mechanical engineering, k. n. toosi university of technology, tehran, iran mojtaba nayenian

faculty of mechanical engineering, k. n. toosi university of technology, tehran, iran gholam reza salehi

mechanical engineering department, islamic azad university, nowshahr branch, iran bahram ghorbani

چکیده

abstract: minimizing the work consumed in refrigeration system is the most effective measure to reduce the cost of products in sub-ambient chemical processes. the introduction of mixed working fluids into refrigeration system in place of pure working fluids is a recent advancement applied in the field. due to the lack of systematic design method for mixed refrigerant cycle (mrc), conventional approaches are largely trial-and-error, and therefore, operations might be far away from optimal operating conditions. in this paper, a novel method for systematic design of mrcs with a given configuration is presented. it combines the benefits of thermodynamics approach and mathematical optimization. an ethylene process was chosen as a typical example of low temperature process. the simulation results show that mrcs can improve the thermodynamic performance of refrigeration system in the case of using optimal operating conditions and also proper arrangement of the cycle components (cycle configuration).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mathematical Method and Thermodynamic Approaches to Design Multi-Component Refrigeration Used in Cryogenic Process Part I: Optimal Operating Conditions

Abstract: Minimizing the work consumed in refrigeration system is the most effective measure to reduce the cost of products in sub-ambient chemical processes. The introduction of mixed working fluids into refrigeration system in place of pure working fluids is a recent advancement applied in the field. Due to the lack of systematic design method for Mixed Refrigerant Cycle (MRC), conventional a...

متن کامل

The Mathematical Method and Thermodynamic Approaches to Design Multi-Component Refrigeration used in Cryogenic Process Part II: Optimal Arrangement

  A refrigeration cycle is a chain of various pieces of equipment including compressors, condensers, evaporators, and expansion devices each of which takes on a particular thermodynamic process duty in the cycle that eventually results in the production of the required refrigeration. The results of optimized mixed refrigerant cycles (MRCs) in Part I show that the configuration of MRC is an eff...

متن کامل

the mathematical method and thermodynamic approaches to design multi-component refrigeration used in cryogenic process part ii: optimal arrangement

a refrigeration cycle is a chain of various pieces of equipment including compressors, condensers, evaporators, and expansion devices each of which takes on a particular thermodynamic process duty in the cycle that eventually results in the production of the required refrigeration. the results of optimized mixed refrigerant cycles (mrcs) in part i show that the configuration of mrc is an effect...

متن کامل

Selection of optimal material and operating conditions in composite manufacturing . Part I : computational tool

The Genetically Optimized Neural Network System (GONNS) is proposed as a human-like decision-making tool for the selection of optimum composite material and operating conditions. Multiple neural networks represent the characteristics of the system after a training process and genetic algorithms find the optimum operating conditions. The error of the GONNS was found to be less than 1% when the n...

متن کامل

Single-cycle mixed-fluid LNG process Part I: Optimal design

In this paper, we discuss the design optimization of a relatively simple LNG process; the PRICO process. A simple economic objective function is stated and used on eight different cases with varying constraints. Important constraints are discussed and the results are compared with the commercial PRICO process and with other publications.

متن کامل

Advanced Exergoeconomic Analysis of C3MR, MFC and DMR ‎Refrigeration Cycles in an Integrated Cryogenic Process

C3MR, MFC, and DMR processes in an integrated LNG-NGL-NRU structure are investigated using the conventional and advanced exergy and exergoeconomic analyses. The results of advanced exergy analysis reveal that in most of the equipment, the highest amount of irreversibility is occurred because of endogenous exergy destruction. In C3MR process, compressor C5 with 9730 kW; in MFC process, compresso...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
gas processing

جلد ۱، شماره ۲، صفحات ۱۳-۲۱

میزبانی شده توسط پلتفرم ابری doprax.com