determination of synthetic phenolic antioxidants in biological fluids based on air-assisted liquid-liquid microextraction followed by gas chromatography-flame ionization detection
نویسندگان
چکیده
an air–assisted liquid–liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography–flame ionization detection has been reported. in this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an aqueous solution by aspirating and dispersing the extraction solvent and sample solution mixture by a syringe. after extraction, phase separation is performed by centrifugation and the enriched analytes in the sedimented phase are determined. the parameters affecting the extraction efficiency including the type and volume of extraction solvent, salt addition, extraction times, and ph are investigated in details. under the optimum extraction conditions, the method shows low limits of detection and quantification between 0.8–1.8 and 2.7-5.6 ng ml–1, respectively. the method is applied to determine some phenolic antioxidants in biological samples and extraction recoveries are ranged from 63 to 81%. enrichment factors are obtained between 315 and 405. the method shows good linearities in the range of 3–6000 ng ml-1 with the correlation coefficients higher than 0.996. relative standard deviations are lower than 8% for intra-day (n=6) and inter-day (n=4) precisions. finally the proposed method is successfully used for determination of the analytes in urine and plasma samples.
منابع مشابه
Determination of Synthetic Phenolic Antioxidants in Biological Fluids Based on Air-assisted Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
An air–assisted liquid–liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography–flame ionization detection has been reported. In this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an a...
متن کاملDetermination of Synthetic Phenolic Antioxidants in Biological Fluids Based on Air- assisted Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
An air-assisted liquid-liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography-flame ionization detection has been reported. In this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an a...
متن کاملDetermination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....
متن کاملDetermination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...
متن کاملDetermination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
OBJECTIVES Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. MATERIALS AND METHODS Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0;...
متن کاملDetermination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
analytical and bioanalytical chemistry researchجلد ۳، شماره ۲، صفحات ۲۳۹-۲۵۱
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023