electrochemical sensor for determination of ascorbic acid using a 2-chlorobenzoyl ferrocene/carbon nanotube paste electrode

نویسندگان

sayed zia mohammadi

department of chemistry, payame noor university, tehran, iran hadi beitollahi

aenvironment department, institute of science and high technology and environmental sciences, graduate university of advanced technology, kerman, iran najmeh nikpour

department of chemistry, payame noor university, tehran, iran rahman hosseinzadeh

department of organic chemistry, faculty of chemistry, university of mazandaran, babolsar, iran

چکیده

a chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2cbf) and carbon nanotube (2cbfcnpe) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. the diffusion coefficient (d = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as the catalytic rate constant (k = 3.7 × 10 3 m-1 s-1) of ascorbic acid oxidation at the surface of 2cbfcnpe were determined using electrochemical approaches. it has been found that under an optimum condition (ph 4.0), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 85 mv less positive than that of an unmodified carbon paste electrode. applying square wave voltammetry, in phosphate buffer solution (pbs) of ph 4.0, the oxidation current increases linearly with two concentration intervals of ascorbic acid, one is 1.0 × 10-7-2.5 × 10-6 m and the other is 2.5 × 10-6-7.0 × 10-5 m. detection limit (3δ) was obtained 64.0 nm. this method was also examined for determination of ascorbic acid in some real samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrochemical Sensor for Determination of Ascorbic Acid Using a 2-Chlorobenzoyl Ferrocene/Carbon Nanotube Paste Electrode

A chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2CBF) and carbon nanotube (2CBFCNPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. The diffusion coefficient (D = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as ...

متن کامل

COBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID

A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...

متن کامل

Simultaneous Voltammetric Determination of Ascorbic Acid and Uric Acid Using a Modified Multiwalled Carbon Nanotube Paste Electrode

This paper describes the development, electrochemical characterization and utilization of novel modified molybdenum (VI) complex-carbon nanotube paste electrode for the electrocatalytic determination of ascorbic acid (AA). The electrochemical profile of the proposed modified electrode was analyzed by cyclic voltammetry (CV) that showed a shift of the oxidation peak potential of AA about 235 mV ...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

Determination of ascorbic acid by a modified multiwall carbon nanotube paste electrode using cetrimonium iodide/iodine

A new modified graphite-multiwall carbon nanotube paste electrode for the determination of ascorbic acid (AA) based on cetrimonium iodide-iodine is described. The electrochemical response characteristics of the modified electrode toward AA were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in phosphate buffer solution (pH 2.0). When compared to activated carbo...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
analytical and bioanalytical chemistry research

جلد ۳، شماره ۲، صفحات ۱۸۷-۱۹۴

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023