direct chemiluminescence determination of oxymorphone using potassium permanganate and polyphosphoric acid
نویسندگان
چکیده
abstract a simple and sensitive chemiluminescence (cl) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. in this method potassium permanganate in polyphosphoric acid was used as cl reagent. using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng ml-1 and 0.34-6.76 µg ml-1 with a sampling rate of 45 samples h−1. the limit of detection was 3.5 ng ml-1 (signal to noise =3) and the percent of relative standard deviations (in 9 replicate measurements) were 3.1% for 135.1 ng ml-1 and 3.6% for 1.4 µg ml-1 oxymorphone. the method is applied to human plasma and synthetic samples. the cl mechanism has been proposed using uv-vis, fluorescence and cl spectra. in this study, detectability of oxymorphone in some other cl systems such as ce(iv)-h2so4, luminol-h2o2, ru(phen)32+-ce(iv) and permanganate-so32- is investigated. cl intensities of twelve narcotics or related drugs were also investigated in the proposed cl system.
منابع مشابه
Direct Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid
Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76...
متن کاملPermanganate-based chemiluminescence analysis of ferulic acid using flow injection.
A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with potassium permanganate in a nitric acid medium. A strong chemiluminescence signal was observed when ferulic acid was injected into an acidic potassium permanganate solution in a flow-cell. The present method a...
متن کاملHighly Sensitive Determination of Ethylenediaminetetraacetic Acid Using a Permanganate Chemiluminescence System Catalyzed by Gold Nanoparticles.
A sensitive and selective chemiluminescence method was developed to determine ethylenediaminetetraacetic acid (EDTA) in water samples. It was observed that gold nanoparticles (AuNPs) catalyzed chemiluminescence (CL) reactions of permanganate-aldehydes which underwent an enhancement effect in the presence of iron(III) ions (Fe(3+)). This effect is more remarkable in the presence of EDTA, and a h...
متن کاملFlow-injection determination of vanadium in seawater samples with acidic potassium permanganate chemiluminescence.
Chemiluminescence from the vanadium and potassium permanganate reaction was studied under acidic conditions to develop a sensitive method for vanadium determination using the formaldehyde enhancement effect. The method was successfully applied to the determination of vanadium in seawater. Experimental parameters were optimized, including acid concentration, potassium permanganate and formaldehy...
متن کاملDetermination of protoberberine alkaloids in medicinal plants based on acidic potassium permanganate chemiluminescence system.
A simple method was established to determine protoberberine alkaloids in Cortex Phellodendri and Rhizoma Coptidis based on an acidic potassium permanganate chemiluminescence (CL) system. The optimum conditions for the CL reaction between protoberberine alkaloids and potassium permanganate were studied in detail. Under the optimum conditions, the linear response ranges for berberine, palmatine a...
متن کاملDetermination of ceftriaxone sodium in pharmaceutical formulations by flow injection analysis with acid potassium permanganate chemiluminescence detection.
Based on the chemiluminescence (CL) emission generated from the oxidation of ceftriaxone sodium alkali hydrolysate by potassium permanganate in polyphosphoric acid (PPA), a novel determination method for ceftriaxone sodium was developed by using a flow-injection technique. The calibration curve appears to be linear in the range between 0.05 and 100 microg mL(-1) with a detection limit (3sigma) ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
analytical and bioanalytical chemistry researchجلد ۴، شماره ۱، صفحات ۱۲۷-۱۳۹
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023