a highly sensitive electrochemicalimmunosensor was developed to detect hcg based on immobilization ofhcg-antibody (anti-hcg) onto robust nanocomposite containing gr, chit,1-methyl-3-octyl imidazolium tetra fluoro borate ionic liquid (il)(gr-il-chit). aunps were used to immobilize hcg antibody on the modifiedelectrode. the amine groups of the antibody are covalently attached toaunps/gr-il-chit nanocomposite. cv, eis and sem were employed to characterizethe assembly process and the performance of the immunosensor. dpv and eisstudies demonstrated that the formation of antibody-antigen complexes decreasedpeak current and increased rct of [fe(cn)6]3−/4−redox pair at the aunps/gr-il-chit/gce. the optimization of the ph ofsupporting electrolyte and the incubation time were studied in details. becauseof the synergistic effect of il, chit and gr and the unique properties ofaunps, the obtained immunosensor exhibited a wide linear response to hcg in tworanges from 0.005-1.484 and 1.484-411.28 (miu ml-1). a relativelylow detection limit of 0.0016 miu ml-1 (s/n = 3) was calculated fromdpv. satisfactory results were obtained for determination of hcg in human serumsamples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunoassay for Human Chorionic Gonadotropin Based on Glassy Carbon Electrode Modified with an Epitaxial Nanocomposite

      A highly sensitive electrochemicalimmunosensor was developed to detect hCG based on immobilization ofhCG-antibody (anti-hCG) onto robust nanocomposite containing Gr, Chit,1-methyl-3-octyl imidazolium tetra fluoro borate ionic liquid (IL)(Gr-IL-Chit). AuNPs were used to immobilize hCG antibody on the modifiedelectrode. The amine groups of the antibody are cova...

متن کامل

Electroanalytical sensing of Asulam based on nanocomposite modified glassy carbon electrode

In this study a facile approach to employ Copper nanoparticle (CuNPs) and multi-walled carbon nanotubes (MWCNT) as the nanomaterial for selective detection of asulam have been investigated. This work reports the electrocatalytic oxidation of asulam on glassy carbon electrodes (GCE) modified with multi-walled carbon nanotubes (MWCNT), ionic liquids (IL), chitosan (Chit) and copper nanoparticles ...

متن کامل

A New Hydroxylamine Electrochemical Sensor Based on an Oxadiazol Derivative and Multi-wall Carbon Nanotuhes Modified Glassy Carbon Electrode

A new hydroxylamine sensor has been fabricated by immobilizing oxadiazol denvative at the surface ol aglassy carbon electrode (GCE) modified by multi-wall carbon nanotube (MIVCNT). The adsorbed thin Illms oroxadiazol derivative on the MWCNT modified GCE show a pair of peaks with surface confined characierisnus.The oxadiazol derivative MWCNI (OMWCNT) modified GCE shows highly catalytic activity ...

متن کامل

An efficient platform based on cupper complex-multiwalled carbon nanotube nanocomposite modified electrode for the determination of uric acid

A new voltammetric sensor for determination of uric acid (UA) by Cuppercomplex- multiwalled carbon nanotube (Cu-complex-CNT) nanocomposite modifiedcarbon paste electrode (CPE) is reported. The electrocatalytic behavior of theCu-complex-CNT nanocomposite modified CPE was studied in pH 2.0 phosphatebuffer solution by chronoamperometry (CA) and cyclic voltammetry (CV) in th...

متن کامل

Correction: Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Polythionine and Multiwalled Carbon Nanotubes

A novel glucose biosensor was fabricated. The first layer of the biosensor was polythionine, which was formed by the electrochemical polymerisation of the thionine monomer on a glassy carbon electrode. The remaining layers were coated with chitosan-MWCNTs, GOx, and the chitosan-PTFE film in sequence. The MWCNTs embedded in FAD were like "conductive wires" connecting FAD with electrode, reduced ...

متن کامل

Fabrication of an Electrochemical Immunosensor for Determination of Human Chorionic Gonadotropin Based on PtNPs/Cysteamine/AgNPs as an Efficient Interface

An ultrasensitive electrochemical immunosensor for the detection of tumor marker human chorionic gonadotropin (hCG) was developed with a limit of detection as low as 2 pg mL-1 in phosphate buffer. The Platinum nanoparticles (PtNPs) were electrodeposited to modify the gold surface and to increase enlarging the electrochemically active sites, resulting in the facilitation of electron exchange. Cy...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
analytical and bioanalytical chemistry research

جلد ۴، شماره ۱، صفحات ۷۹-۹۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023