analysis of relative biological effectiveness of proton beams and iso-effective dose profiles using geant4
نویسندگان
چکیده
background: the assessment of rbe quantity in the treatment of cancer tumors with proton beams in treatment planning systems (tps) is of high significance. given the significance of the issue and the studies conducted in the literature, this quantity is fixed and is taken as equal to 1.1. objective: the main objective of this study was to assess rbe quantity of proton beams and their variations in different depths of the tumor. this dependency makes rbe values used in tps no longer be fixed as they depend on the depth of the tumor and therefore this dependency causes some changes in the physical dose profile. materials and methods: the energy spectrum of protons was measured at various depths of the tumor using proton beam simulations and well as the complete simulation of a cell to a pair of dna bases through monte carlo geant4. the resulting energy spectrum was used to estimate the number of double-strand breaks generated in cells. finally, rbe values were calculated in terms of the penetration depth in the tumor. results and conclusion: the simulation results show that the rbe value not fixed terms of the depth of the tumor and it differs from the clinical value of 1.1 at the end of the dose profile and this will lead to a non-uniform absorbed dose profile. therefore, to create a uniform impact dose area, deep-finishing systems need to be designed by taking into account deep rbe values.
منابع مشابه
Analysis of Relative Biological Effectiveness of Proton Beams and Iso-effective Dose Profiles Using Geant4
Background: The assessment of RBE quantity in the treatment of cancer tumors with proton beams in treatment planning systems (TPS) is of high significance. Given the significance of the issue and the studies conducted in the literature, this quantity is fixed and is taken as equal to 1.1.Objective: The main objective of this study was to assess RBE quantity of proton beams and their variations ...
متن کاملAnalysis of Relative Biological Effectiveness of Proton Beams and Iso-effective Dose Profiles Using Geant4
BACKGROUND The assessment of RBE quantity in the treatment of cancer tumors with proton beams in treatment planning systems (TPS) is of high significance. Given the significance of the issue and the studies conducted in the literature, this quantity is fixed and is taken as equal to 1.1. OBJECTIVE The main objective of this study was to assess RBE quantity of proton beams and their variations...
متن کاملMicrodosimetric relative biological effectiveness of therapeutic proton beams.
When compared to photon beams, particle beams have distinct spatial distributions on the energy depositions in both the macroscopic and microscopic volumes. In a macroscopic volume, the absorbed dose distribution shows a rapid increase near the particle range, that is, Bragg peak, as particle penetrates deep inside the tissue. In a microscopic volume, individual particle deposits its energy alo...
متن کاملRelative biological effectiveness of therapeutic proton beams for HSG cells at Japanese proton therapy facilities
We investigated the relative biological effectiveness (RBE) of therapeutic proton beams at six proton facilities in Japan with respect to cell lethality of HSG cells. The RBE of treatments could be determined from experimental data. For this purpose, we used a cell survival assay to compare the cell-killing efficiency of proton beams. Among the five linear accelerator (LINAC) X-ray machines at ...
متن کاملCalculation of dose, dose equivalent, and relative biological effectiveness for high charge and energy ion beams.
The Green's function for the transport of ions of high charge and energy is utilized with a nuclear fragmentation database to evaluate dose, dose equivalent, and RBE for C3H10T1/2 cell survival and neoplastic transformation as a function of depth in soft tissue. Such evaluations are useful to estimates of biological risk for high altitude aircraft, space operations, accelerator operations, and ...
متن کاملErratum to ‘Microdosimetric calculation of relative biological effectiveness for design of therapeutic proton beams’†
The authors attempt to establish the relative biological effectiveness (RBE) calculation for designing therapeutic proton beams on the basis of microdosimetry. The tissue-equivalent proportional counter (TEPC) was used to measure microdosimetric lineal energy spectra for proton beams at various depths in a water phantom. An RBE-weighted absorbed dose is defined as an absorbed dose multiplied by...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of biomedical physics and engineeringجلد ۷، شماره ۲ Jun، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023