subcutaneous connective tissue reaction to a new nano zinc-oxide eugenol sealer in rat model

نویسندگان

salma omidi mazandaran university

maryam javidi

mina zarei

siavash mushakhian

چکیده

introduction: the aim of this animal study was to evaluate the histological response of the new nano zinc-oxide eugenol (nzoe) sealer in comparison with pulp canal sealer (zoe based) and ah-26 (epoxy resin sealer). methods and materials: a total of 27 wistar rats were used. four polyethylene tubes were implanted in the back of each rat (three tubes containing the test materials and an empty tube as a control). then, 9 animals were sacrificed at each interval of 15, 30 and 60 days, and the implants were removed with the surrounding tissues.samples were evaluated for the presence of inflammatory cell (mononuclear cell), vascular changes, fibrous tissue formation and present of giant cell. comparisons between groups and time-periods were performed using the kruskal-wallis and mann-whitney u non-parametric tests. the level of significance was set at 0.05. results: no significant difference was observed in tissue reactions and biocompatibility pattern of three sealers during 3 experimental periods ( p <0.05). in all groups the tissue behavior showed tendency to decrease the irritation effect over time. conclusion: the new nano zinc-oxide eugenol sealer has histocompatibility properties comparable to conventional commercial sealers.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model

INTRODUCTION The aim of this animal study was to evaluate the histological response of the new nano zinc-oxide eugenol (NZOE) sealer in comparison with Pulp Canal Sealer (ZOE based) and AH-26 (epoxy resin sealer). METHODS AND MATERIALS A total of 27 Wistar rats were used. Four polyethylene tubes were implanted in the back of each rat (three tubes containing the test materials and an empty tub...

متن کامل

Tooth Discoloration Resulting from a Nano Zinc Oxide-Eugenol Sealer

INTRODUCTION A desirable quality of any endodontic sealer is its ability to be tooth color friendly. Therefore the aim of the present study was to evaluate the tooth discoloration potential of a nano zinc oxide-eugenol (NZOE) sealer. METHODS AND MATERIALS In order to evaluate tooth discoloration, the pulp chamber of 60 human maxillary central and lateral incisors were filled with one of the s...

متن کامل

Cytotoxicity of a New Nano Zinc-Oxide Eugenol Sealer on Murine Fibroblasts

INTRODUCTION The aim of this study was to evaluate the cytotoxicity of a new nano zinc-oxide eugenol (NZOE) sealer in comparison with AH-26 and Pulpdent root canal sealers. METHODS AND MATERIALS The L929 mouse fibroblast cells were cultivated and incubated for 24, 48 or 72 h with different dilutions (1/1, 1/2, 1/4, 1/8, 1/16 and 1/32) of culture media previously exposed to either of the test ...

متن کامل

tooth discoloration resulting from a nano zinc oxide-eugenol sealer

introduction: a desirable quality of any endodontic sealer is its ability to be tooth color friendly. therefore the aim of the present study was to evaluate the tooth discoloration potential of a nano zinc oxide-eugenol (nzoe) sealer. methods and materials: in order to evaluate tooth discoloration, the pulp chamber of 60 human maxillary central and lateral incisors were filled with one of the s...

متن کامل

cytotoxicity of a new nano zinc-oxide eugenol sealer on murine fibroblasts

introduction: the aim of this study was to evaluate the cytotoxicity of a new nano zinc-oxide eugenol (nzoe) sealer in comparison with ah-26 and pulpdent root canal sealers. methods and materials: the l929 mouse fibroblast cells were cultivated and incubated for 24, 48 or 72 h with different dilutions (1/1, 1/2, 1/4, 1/8, 1/16 and 1/32) of culture media previously exposed to either of the test ...

متن کامل

Setting Reaction of Zinc Oxide and Eugenol !

Zinc oxide-eugenol mixtures have been used in dentistry for a number of years. The setting mechanism of these mixtures was investigated. X-rav diffraction dat a and electron photomicrovaphs g ive ~vid~nce that a crystll:lline compound is formed. Analysis and molecular-weight dettrml.nat lons show t hat th,s compound corresponds t o the empirical formula (OIOH l.' O2) 2 Zn, ztnC eugenolate. Infr...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian endodontic journal

جلد ۱۲، شماره ۱، صفحات ۶۴-۶۹

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023