emergent ct diagnosis of right ventricular rupture caused by central venous catheter injury
نویسندگان
چکیده
diagnosis of cardiac tamponade has been mainly based on clinical features and echocardiography. however, ct may be an initial tool for the evaluation of cardiac tamponade because cutting edge ct is increasingly being installed in the emergency room, and presentation of cardiac tamponade can be nonspecific. importantly, ct has better spatial resolution compared with echocardiography. thus, identification of the etiology of cardiac tamponade is possible on ct. we report a case of cardiac tamponade demonstrating direct leakage of contrast material from the right ventricle into the pericardial space caused by central venous catheter injury diagnosed on ct.
منابع مشابه
Cardiac tamponade caused by central venous catheter in two newborns.
Cardiac tamponade secondary to the use of central venous catheter is a rare complication; however, it is potentially reversible when it is caught in time. We report two cases of cardiac tamponade that was diagnosed using a transthoracic echocardiography, followed by urgent pericardiocentesis and surgical pericardial drainage as a complication from umbilical venous catheterization. In one case, ...
متن کاملThe successful withdrawal of a migrated central venous catheter
Background: Central venous catheters (CVCs) have been used widely in clinics. These catheters are also recommended for children and infants receiving chemotherapy and total parenteral nutrition (TPN) and etc. In this paper, we present migrated fractured control line of the heart of a girl. Case Presentation: A 2.5 year old girl with migrated of the fractured central line into the heart. In the ...
متن کاملCentral venous catheter fracture.
665 The Journal of the American Osteopathic Association August 2014 | Vol 114 | No. 8 An 18-year-old woman presented with a 1-day history of edema and erythema associated with a port central venous access device of the anterior left chest wall. The patient reported difficulty with catheter flushing for 2 days. Medical history included severe gastroparesis requiring placement of the catheter 2 m...
متن کاملRight ventricular volume measurement by conductance catheter.
Continuous ventricular volume measurement by the conductance method assumes a homogeneous electrical field dispersed throughout and contained within the ventricle. Because of dense trabeculation and complex geometry, right ventricular (RV) volume description by this method may be seriously compromised. This study sought to determine the accuracy and limitations of RV volume measurement by condu...
متن کاملPerforation of the right ventricle and cardiac tamponade caused by a venous catheter.
A case is reported in which a venous catheter perforated the right ventricle and caused cardiac tamponade. Methods recommended to avoid such complications include limiting the length of the radio-opaque catheter, and modifications to the catheter tip.
متن کاملCentral Venous Catheter Intravascular Malpositioning: Causes, Prevention, Diagnosis, and Correction
Despite the level of skill of the operator and the use of ultrasound guidance, central venous catheter (CVC) placement can result in CVC malpositioning, an unintended placement of the catheter tip in an inadequate vessel. CVC malpositioning is not a complication of central line insertion; however, undiagnosed CVC malpositioning can be associated with significant morbidity and mortality. The obj...