influence of root canal curvature on the accuracy of root zx electronic foramen locator: an in vitro study

نویسندگان

masoud saatchi

shiva iravani

mehrdad akhavan khaleghi

amin mortaheb

چکیده

introduction: the aim of this in vitro study was to evaluate the correlation between accuracy of root zx electronic foramen locator and root canal curvature. methods and materials: one hundred and ten extracted mandibular molars were selected. access cavity was prepared and coronal enlargement of mesiobuccal canal was performed. a #10 flexofile was inserted into the mesiobuccal canal, and a radiography was taken to measure the degree of curvature by schneider's method. the actual working length (awl) was defined by inserting the file until its tip could be observed at a place tangential to the major apical foramen and then 0.5 mm was subtracted from this measurement. for the electronic working length (ewl) measurement, the apical 3 or 4 mm of the root was embedded in alginate as the electrolyte material. the file was inserted into the root canal to the major foramen, until the apex reading was shown on the electronic device and then pulled back until the visual display showed the 0.5-mm mark. the awl was subtracted from the ewl to define the distance between the file tip and the point 0.5 mm coronal to the major apical foramen. data were analyzed using the pearson’s correlation coefficient. results: the accuracy of root zx within ±0.1 mm and ±0.5 mm was 38.2% and 94.6%, respectively. there was no correlation between the distance from the ewl to the awl and the degree of root canal curvature (r=0.097, p =0.317). conclusion: root canal curvature did not influence the accuracy of root zx foramen locator.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Root Canal Curvature on the Accuracy of Root ZX Electronic Foramen Locator: An In Vitro Study

INTRODUCTION The aim of this in vitro study was to evaluate the correlation between accuracy of Root ZX electronic foramen locator and root canal curvature. METHODS AND MATERIALS One hundred and ten extracted mandibular molars were selected. Access cavity was prepared and coronal enlargement of mesiobuccal canal was performed. A #10 Flexofile was inserted into the mesiobuccal canal, and a rad...

متن کامل

The accuracy of root canal measurements using the Mini Apex Locator and Root ZX-II: an evaluation in vitro.

OBJECTIVE The aim of this in vitro study was to compare the capacity of the Root ZX-II and Mini Apex Locator, electronic apex locators (EALS), to prevent overestimated working length. STUDY DESIGN Forty extracted human teeth were used for the study. The cervical portion of each canal was flared using Gates Glidden drills and the teeth were embedded in an alginate model. Canals were irrigated ...

متن کامل

Root ZX Electronic Foramen Locator: An Ex Vivo Study of Its Three Models' Precision and Reproducibility

Although Root ZX is considered the gold standard electronic foramen locator (EFL), two variations of this device were launched, however without different operating mechanisms. This investigation aims to evaluate the precision of Root ZX (RZX), Root ZX II (RII), and Root ZX Mini (RM) EFLs. After access cavity preparation, 32 mandibular single rooted human premolars had their real length measured...

متن کامل

An in vivo evaluation of Root ZX electronic apex locator.

The Root ZX has been introduced recently as a device capable of performing accurately in the presence of sodium hypochlorite, blood, water, local anesthetic, and pulpal tissues. The Root ZX was used to locate the apical foramen in 26 root canals of vital teeth. After extraction of the teeth, a stereomicroscope was used to confirm visually the relationship of the tip of the endodontic file to th...

متن کامل

Accuracy of electronic apex locator in enlarged root canals with different root canal irrigants: an in vitro study.

AIM To evaluate the accuracy of Root ZX-II (J Morita Corp) apex locator in enlarged root canals with different root canal irrigants. MATERIALS AND METHODS 48 freshly extracted single rooted mandibular premolar teeth were used. The apical enlargement was done up to #45 K-file as the master apical file (MAF). The teeth were randomly divided into 4 groups and mounted in an experimental apparatus...

متن کامل

The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files.

Numerous apex locator studies have been performed. Generally, they use only stainless-steel hand files for testing purposes. Today many clinicians use both stainless-steel and nickel-titanium files during the treatment of a case. Given the widespread use of nickel-titanium files, a comparison of the accuracy in determining length with an apex locator using stainless-steel and nickel-titanium fi...