application of fluka code to gamma-ray attenuation, energy deposition and dose calculations

نویسندگان

n. demir physics department, faculty of arts and sciences, uludag university, gorukle campus,16059, bursa, turkey

u. akar tarim physics department, faculty of arts and sciences, uludag university, gorukle campus,16059, bursa, turkey

o. gurler physics department, faculty of arts and sciences, uludag university, gorukle campus,16059, bursa, turkey

چکیده

background: in radiation therapy, water is the phantom material of choice, both for reference and for relative dosimetry measurements. solid phantoms, however, are more useful for routine measurements because they tend to be more robust and easier to set up than water phantoms. materials and methods: fluka input data cards have been arranged in sequential order. a simple cylindrical geometry with the axis along the z-direction was described in the input file. a beam of 1x105 gamma-rays was directed towards the materials in the z-direction. the results of photon transmission, i/i0, were obtained from output files for each of the material thicknesses using the usrbdx score card. the usrbin score card was also included in the input file, and the energy deposited by 661.6 kev photons into water and solid phantom materials has been obtained. results: the values of linear attenuation coefficients calculated by fluka are closer to experimentally obtained ones. the values of the linear attenuation coefficients derived from xcom are greater than those derived from the fluka transmission data. the values of dose absorbed in perspex are smaller than those of other materials, which are closer to each other.  conclusion: rmi-457, plastic water and rw solid phantoms can be used for radiation dosimetry of photons in the energy range from 59.5 to 1332.5 kev. from the investigation of absorbed dose values versus thickness of absorber, perspex is not a suitable equivalent to water for the tested energies.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of FLUKA code to gamma-ray attenuation, energy deposition and dose calculations

Background: In radiation therapy, water is the phantom material of choice, both for reference and for relative dosimetry measurements. Solid phantoms, however, are more useful for routine measurements because they tend to be more robust and easier to set up than water phantoms. Materials and Methods: FLUKA input data cards have been arranged in sequential order. A simple cylindrical geometry wi...

متن کامل

Fluka Calculations of Gamma Spectra at Bessy

Since 22nd October 2012 the synchrotron light source BESSY is operated in top-up mode. Losses of electrons during injection cause an electromagnetic cascade, that consists of high energetic photons of the bremsstrahlung, and secondary electrons and positrons from the pair creations. The bremsstrahlung spectrum has a maximum at 1.022 MeV owing to pair creations. The spectrum has a high energetic...

متن کامل

Calculations of Gamma Ray Dose from Gamma Ray Bursters and Nearby Supernovae

INTRODUCTION Supernovae and gamma ray bursters (possibly caused by “hypernovae”) are the most energetic known events in the Universe. Supernovae release approximately 10 ergs of energy in the form of photons, neutrinos, and kinetic energy imparted to debris from the explosion. Hypernovae release approximately 10 ergs of gamma ray energy alone (1). Some researchers have speculated that nearby su...

متن کامل

Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...

متن کامل

Simulation of gamma-ray gamma rays by composite shields compared to the lead protection using the MCNPX code

In this study, cobalt 60 with a mean energy of (1.25 Mev) was used as a photonic source to investigate the effect of decreasing gamma-ray intensity by materials and polymer composite using MCNPX code. First, we investigated the effect of thickness and density on the reduction of gamma ray intensity, and then the comparison between the lead protector, tungsten and polymer composite in several th...

متن کامل

the role of russia in transmission of energy from central asia and caucuses to european union

پس ازفروپاشی شوروی،رشد منابع نفت و گاز، آسیای میانه و قفقاز را در یک بازی ژئوپلتیکی انرژی قرار داده است. با در نظر گرفتن این منابع هیدروکربنی، این منطقه به یک میدانجنگ و رقابت تجاری برای بازی های ژئوپلتیکی قدرت های بزرگ جهانی تبدیل شده است. روسیه منطقه را به عنوان حیات خلوت خود تلقی نموده و علاقمند به حفظ حضورش می باشد تا همانند گذشته گاز طبیعی را به وسیله خط لوله مرکزی دریافت و به عنوان یک واس...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۵، شماره ۱، صفحات ۱۲۳-۱۲۸

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023