automatic detection of liver tumor motion by fluoroscopy images

نویسندگان

h. w. zhang department of radiotherapy; jiang-xi cancer hospital; nanchang 330029, china

y. l. wang department of radiation oncology, pla general hospital, beijing 100853, china

y. l. wang department of radiation oncology, pla general hospital, beijing 100853, china

چکیده

background: a method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. materials and methods: the method was based on the following idea: (i) before treatment, a series of fluoroscopic images corresponding to different breathing phases and tumor positions were acquired after patient set-up; (iii) the wavelet transform method and canny edge detection algorithm were used to detect motion trajectory of the diaphragm; (iv) the motion curves of center of lipiodol in the images were obtained by mathematical morphology and median filtering algorithm. the method was evaluated using by five sequences of fluoroscopic images from tace patients who received transcatheter arterial chemoembolization therapy.  results: the position of liver tumor was significantly affected by respiratory motion; the motion trajectories of the diaphragm and lipiodolagreed well with the manually marked locations in amplitude and period; the motion trajectories of the diaphragm and lipiodol almost had similar period and amplitude in one  treatment fraction. the respiratory period and amplitude of the same patient in different fractions had no significant differences; however, the difference was obvious for different patients. the proposed lipiodol detection methods can effectively reflect the relevant rules of tumor location caused by respiratory movement. conclusion: direct tracking of liver tumor motion in fluoroscopic images is feasible. the automatic detection method can reflect the characteristics of respiratory and tumor motions, which can save much time and significantly improve measurement precision compared with manual measurement.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic detection of liver tumor motion by fluoroscopy images

Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...

متن کامل

An Automatic Detection of the Fire Smoke Through Multispectral Images

One of the consequences of a fire is smoke. Occasionally, monitoring and detection of this smoke can be a solution to prevent occurrence or spreading a fire. On the other hand, due to the destructive effects of the smoke spreading on human health, measures can be taken to improve the level of health services by zoning and monitoring its expansion process. In this paper, an automated method is p...

متن کامل

Tumor Detection and Morphology Assessment in the Liver Tissue Using an Automatic Tactile Robot

In this paper an automatic examination robot was developed to improve the process of cancer detection, tumor localization and geometrical shape diagnosis. A uniformly distributed compressive load was applied to the top tissue surface and the resultant mechanical stress was measured that was employed for the tumor diagnosis task. The experimental examinations were performed on the soft tissue of...

متن کامل

extremal region detection guided by maxima of gradient magnitude

a problem of computer vision applications is to detect regions of interest under dif- ferent imaging conditions. the state-of-the-art maximally stable extremal regions (mser) detects affine covariant regions by applying all possible thresholds on the input image, and through three main steps including: 1) making a component tree of extremal regions’ evolution (enumeration), 2) obtaining region ...

Automatic Classification of Benign And Malignant Liver Tumors In Ultrasound Images

Introduction: Differentiation of benign and malignant liver tumors is very important for finding appropriate treatment procedure. Human eyes sometime are not able to diagnose the type of liver tumor. Texture analysis is considered as a suitable method to increase the diagnostic power of medical images. In this study texture analysis is employed in order to classification of ben...

متن کامل

Automatic Brain Tumor Detection in T2-weighted Magnetic Resonance Images

1Deptartment of Telecommunications, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, 612 00 Brno, Czech Republic, [email protected] 2Pattern Recognition and Image Processing Group, Institute of Computer Graphics and Algorithms, Faculty of Informatics, Vienna University of Technology, Favoritenstr. 9/186-3, A-1040 Vienna, Austria 3Ins...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۵، شماره ۱، صفحات ۴۹-۶۱

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023