accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (epid)

نویسندگان

s. r. mahdavi medical physics department of iran university of medical sciences, tehran, iran

e. jazayeri gharehbagh department of radiology and radiotherapy technology, school of allied health sciences, tehran university of medical sciences, tehran, iran

b. mofid 3radiotherapy department of shahid beheshti university of medical sciences, tehran, iran

a. h. jafari research center of biomedical technology and robotics, tehran university of medial sciences, tehran, iran

چکیده

background: to correct patient positioning errors (setup errors) during prostate cancer treatment using epid and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. materials and methods: fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field imrt planning technique. the plan was prepared in accordance with icru 50 guidance (ptv to receive 95-107% dose). the software program reconstructed the three-dimensional position of the markers from the different beams eye views (bev). the discrepancies of the seeds’ positions (prostate surrogate) between plan and daily images were calculated three dimensionally. then, necessary corrections were applied to match the prostate fiducial markers in the portal image with the bev image in the planned one by moving the couch in the x, y and z directions. results: data from 15 patients and 469 fractions of radiotherapy were analyzed in this study. two sets of data were available from epid software before and after 3d set-up corrections. the mean of the population displacement in left /right (l/r), anterior/posterior (a/p) and crania/caudal (c/c) directions were 0.5, -1.0 and 2.4mm before, and -0.1, -0.5 and 0.9mm after corrections, respectively. the systematic and random errors for the measured populations in the three mentioned directions were 2.4, 2.7 and 2mm and 6.4, 5.9 and 6.1mm before corrections, and 1.1, 2.4 and 1.4mm and 3.8, 3.9 and 3.6mm after corrections, correspondingly. conclusion: this study provides further evidence that using gold markers in the prostate improves dose delivery to the prostate. also, it has been demonstrated that the epid can be a powerful tool in the reduction of treatment setup errors and the quality assurance and verification of complex treatments.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...

متن کامل

In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motion.

PURPOSE To investigate the use of a commercially available video-based EPID for in vivo dosimetry during treatment of prostate cancer patients. METHODS For 10 prostate cancer patients, the inter-fraction variation within measured portal dose images (PDIs) was assessed and measured PDIs were compared with corresponding predicted PDIs based on the planning CT scan of the patient. RESULTS For ...

متن کامل

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

Comparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications

Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...

متن کامل

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

Image-guided prostate radiotherapy: analysis of inter- fractional setup errors

Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۵، شماره ۱، صفحات ۳۹-۴۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023