three-phase to single-phase matrix converters: new topology based on new control method
نویسندگان
چکیده
in this paper, a new topology is proposed for three-phase to single-phase matrix converters, where more voltage levels are produced in the output in comparison with the conventional topologies. in addition, a new control method based on minimum error between the generated and the desired output voltages is proposed for three-phase to single-phase matrix converters. in the proposed control method, the output voltage is generated by the mixture of different pieces of the input voltages. in other words, by applying this method, the matrix converter operates like a multilevel converter without requiring to any extra elements. due to the proposed control method, the desired output voltage can be generated with an acceptable accuracy even with unbalanced and significantly distorted input voltage waveforms. the other advantage of the proposed control method is reduction of number of switching which allows low speed semiconductors application in the structure of bidirectional switches required by matrix converters and also reduction in switching losses. using this strategy, the stresses on load are significantly reduced. as a result, the electromagnetic interference (emi) is considerably decreased in comparison with the other conventional control methods. simulation results in pscad/emtdc software and experimental results show that the proposed control method operates correctly and confirm the perfect performance of the proposed topology.
منابع مشابه
Three-Phase to Single-Phase Matrix Converters: New Topology Based on New Control Method
In this paper, a new topology is proposed for three-phase to single-phase matrix converters, where more voltage levels are produced in the output in comparison with the conventional topologies. In addition, a new control method based on minimum error between the generated and the desired output voltages is proposed for three-phase to single-phase matrix converters. In the proposed control metho...
متن کاملThree-Phase to Single-Phase Matrix Converters: New Topology Based on New Control Method
In this paper, a new topology is proposed for three-phase to single-phase matrix converters, where more voltage levels are produced in the output in comparison with the conventional topologies. In addition, a new control method based on minimum error between the generated and the desired output voltages is proposed for three-phase to single-phase matrix converters. In the proposed control metho...
متن کاملA New Topology for Interline Dynamic Voltage Restorer Based on Direct Three-Phase Converter
In this paper, a new topology for Interline Dynamic Voltage Restorer (IDVR) is proposed. This topology contains two direct three-phase converters which have been connected together by a common fictitious dc-link. According to the kind of the disturbances, both of the converters can be employed as a rectifier or inverter. The converters receive the required compensation energy from the gird thro...
متن کاملA New Circuit for Three-phase to Three-phase Ac/ac Matrix Converters
The conventional AC/AC matrix converter uses 9 bidirectional switches. The 3×3 switches give 512 combinations of switching states, which are decreased to only 27 feasible states, if the two basic rules (preventing the short-circuit and open-circuit) to operate the converters safely are applied. The output voltage of a basic matrix converter is limited to 866 . 0 2 3 ≈ of the input voltage. In t...
متن کاملA New Control Method for Single-Phase Grid-Connected Inverter Using Instantaneous Power Theory
Because of installation for local consumers and since it is free of all contaminations, connecting photovoltaic cells to the grid via single-phase inverter is significantly on the rise. In this paper, a new simple current control is proposed for a single-phase grid-connected voltage source inverter. Using the PQ theory and modelling a single-phase system as an unbalanced three-phase system, a m...
متن کاملA New Pulsating Power Elimination Method for Single-Phase PWM AC/DC Converters with Minimum Voltage and Current Stress
An inherent problem of single-phase rectifiers is the existence of a pulsating portion in the input power, which pulsates at twice the grid frequency. If this pulsating power is transferred to the DC-link, it causes a significant amount of second-order harmonic at the output voltage. Since in many applications, such a high level of DC oscillation is not acceptable, so the pulsating power must b...