analysis and optimization of a fission chamber detector using mcnp4c and srim monte carlo codes
نویسندگان
چکیده
in this study, a general theoretical model to foresee and calculate the current-voltagecharacteristics in a plateau zone and the associated efficiency of the neutron detector (sensitivity) is presented. this study is to complete the previous studies in this field. the model also considers electric field distortion resulting from the charge collection effect. the characteristics curve is obtained as a function of fission rate, chamber geometry, and filling gas pressure. the output current at the saturation domain is calculated. the applied voltages about two phenomena, recombination and avalanche, for working the chamber in an ionization zone are an important part of the calculation. in developing the theoretical model, the mcnp code for fission rate, the srim code for electron-ion pair and geant4 for gamma sensitivity calculations were used.
منابع مشابه
Comparison of MCNP4C, 4B and 4A Monte Carlo codes when calculating electron therapy depth doses
ABSTRACT Background: accurate methods of radiation therapy dose calculation. There are different Monte Carlo codesfor simulation of photons, electrons and the coupled transport of electrons and photons. MCNPis a general purpose Monte Carlo code that can be used for electron, photon and coupledphoton-electron transport.Monte Carlo simulation of radiation transport is considered to be one of the ...
متن کاملMonte Carlo Simulation for Treatment Planning Optimization of the COMS and USC Eye Plaques Using the MCNP4C Code
Introduction: Ophthalmic plaque radiotherapy using I-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. Radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. This treatment allows for a localized radiation dose delivery to the tumor with a ...
متن کاملa phonological contrastive analysis of kurdish and english
deposite the different criticisms on contrastive analysis it has been proved that the results of it(when processed)can be usuful in a tefl environment,specially at the level of phonology.this study is an attempt to compare and contrast the sound systems of kurdish and english for pedagogical aims. the consonants,vowels,stress and intonation of the twolanguages are described by the same model-ta...
15 صفحه اولcomparison of mcnp4c, 4b and 4a monte carlo codes when calculating electron therapy depth doses
abstract background: accurate methods of radiation therapy dose calculation. there are different monte carlo codesfor simulation of photons, electrons and the coupled transport of electrons and photons. mcnpis a general purpose monte carlo code that can be used for electron, photon and coupledphoton-electron transport.monte carlo simulation of radiation transport is considered to be one of the ...
متن کاملa contrastive analysis of concord and head parameter in english and azerbaijani
این پایان نامه به بررسی و مقایسه دو موضوع مطابقه میان فعل و فاعل (از نظر شخص و مشار) و هسته عبارت در دو زبان انگلیسی و آذربایجانی می پردازد. اول رابطه دستوری مطابقه مورد بررسی قرار می گیرد. مطابقه به این معناست که فعل مفرد به همراه فاعل مفرد و فعل جمع به همراه فاعل جمع می آید. در انگلیسی تمام افعال، بجز فعل بودن (to be) از نظر شمار با فاعلشان فقط در سوم شخص مفرد و در زمان حال مطابقت نشان میدهند...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of science and technology (sciences)ISSN 1028-6276
دوره 33
شماره 3 2009
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023