nickel ion release from three types of nickel-titanium-based orthodontic archwires in the as-received state and after oral simulation

نویسندگان

barat-ali ramazanzadeh department of orthodontics, school of dentistry, mashhad university of medical sciences, mashhad, iran

farzaneh ahrari dental research center, mashhad university of medical sciences

berahman sabzevari department of orthodontics, school of dentistry, rafsanjan university of medical sciences, rafsanjan, iran

samaneh habibi

چکیده

background and aims. this study aimed to investigate release of nickel ion from three types of nickel-titanium-based wires in the as-received state and after immersion in a simulated oral environment. materials and methods. forty specimens from each of the single-strand niti (rematitan “lite”), multi-strand niti (speed supercable) and copper niti (damon copper niti) were selected. twenty specimens from each type were used in the as-received state and the others were kept in deflected state at 37ºc for 2 months followed by autoclave sterilization. the as-received and recycled wire specimens were immersed in glass bottles containing 1.8 ml of artificial saliva for 28 days and the amount of nickel ion released into the electrolyte was determined using atomic absorption spectrophotometry. results. the single-strand niti released the highest quantity of nickel ion in the as-received state and the multi-strand niti showed the highest ion release after oral simulation. the quantity of nickel ion released from damon copper niti was the lowest in both conditions. oral simulation followed by sterilization did not have a significant influence on nickel ion release from multi-strand niti and damon copper niti wires, but single-strand niti released statistically lower quantities of nickel ion after oral simulation. conclusion. the multi-strand nature of supercable did not enhance the potential of corrosion after immersion in the simulated oral environment. in vitro use of nickel-titanium-based archwires followed by sterilization did not significantly increase the amount of nickel ion released from these wires.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nickel Ion Release from Three Types of Nickel-titanium-based Orthodontic Archwires in the As-received State and After Oral Simulation

Background and aims. This study aimed to investigate release of nickel ion from three types of nickel-titanium-based wires in the as-received state and after immersion in a simulated oral environment. Materials and methods. Forty specimens from each of the single-strand NiTi (Rematitan "Lite"), multi-strand NiTi (SPEED Supercable) and Copper NiTi (Damon Copper NiTi) were selected. Twenty specim...

متن کامل

Thermal analysis of as-received and clinically retrieved copper-nickel-titanium orthodontic archwires.

OBJECTIVE To compare as-received copper-nickel-titanium (CuNiTi) archwires to those used in patients by means of differential scanning calorimetry (DSC). Also, the thermal or phase properties of 27 degrees C, 35 degrees C, and 40 degrees C CuNiTi archwires were studied to ascertain if their properties match those indicated by the manufacturer. MATERIALS AND METHODS Six wires of 27 degrees C, ...

متن کامل

The Mechanical Effects of Flaming Nickel-Titanium Orthodontic Archwires

Objective: To assess the mechanical effects of nickel-titanium orthodontic archwire flaming and their distribution along the wire. Methodology: Two sizes of pre-formed austenitic nickel-titanium archwires were tested (n=10). The terminal 5mm of each wire was heated for five seconds using a butane lighter. Micro-hardness testing was used to determine the heat-affected zone for all wires. Cantile...

متن کامل

Surface characteristics of retrieved coated and nickel-titanium orthodontic archwires.

OBJECTIVE The purpose of this study was to investigate the effects of oral fluids and archwire-bracket friction on the surface characteristics of NiTi alloy orthodontic archwires with/without aesthetic coating, in vivo for 2-3 months. MATERIALS AND METHODS Different cross-sections of NiTi Archwires (DENTSPLY GAC International) and Titanol Cosmetic Archwires (FORESTADENT® USA Inc.) were examin...

متن کامل

Mechanical Properties of Copper-Nickel-Titanium Archwires

MECHANICAL PROPERTIES OF COPPER-NICKEL-TITANIUM ORTHODONTIC WIRES Margaret Rosen, D.M.D. Marquette University, 2016 Introduction: The initial phase of orthodontic therapy relies on flexible wires, usually composed of a nickel-titanium alloy, to apply a substantially constant load during tooth movement. Copper has been added to nickel-titanium archwires, resulting in an alloy with potential clin...

متن کامل

Effects of three different mouthwashes on the surface characteristics of nickel-titanium and Stainless steel archwires in orthodontics

Introduction: Patients are recommended regular using of mouthwashes to control dental caries or periodontal diseases since orthodontic treatment may have detrimental effects on the tooth structures. However, chemical agents may potentially damage metal components of orthodontic appliances. The aim of this study was to evaluate the influence of three mouthwashes on the surface characteristics of...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dental research, dental clinics, dental prospects

جلد ۸، شماره ۲، صفحات ۷۱-۷۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023