new formula for calculation of cobalt-60 percent depth dose
نویسندگان
چکیده
introduction: on the basis of percent depth dose (pdd) calculation, the application of dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. the aim of this study is to introduce a new formula for calculating the centeral axis percent depth doses of cobalt-60 beam. materials and methods: in the present study, based on the british journal of radiology (bjr) table, nine new formulas are developed and evaluated for depths of 0.5 - 30 cm and fields of )4 4( × ) 45 45 ( × − cm 2 . to evaluate the agreement between the formulas and the table, the average of the absolute differences between the values was used and the formula with the least average was selected as the best fitted formula. the microsoft excel 2000 and the datafit 8.0 soft wares were used to perform the calculations. results: the results of this study indicated that one amongst the nine formulas gave a better agreement with the pdds listed in the table of bjr. the new formula has two parts in terms of log (a/p). the first part as a linear function with the depth in the range of 0.5 to 5 cm and the other one as a second order polynomial with the depth in the range of 6 to 30 cm. the average of the differences between the tabulated and the calculated data using the formula ( δ ) is equal to 0.3152. discussion and conclusion: therefore, the calculated percent depth dose data based on this formula has a better ageement with the published data for cobalt-60 source. this formula could be used to calculate the percent depth dose for the depths and the field sizes not listed in the bjr table.
منابع مشابه
New formula for Calculation of Cobalt-60 Percent Depth Dose
Introduction: On the basis of percent depth dose (PDD) calculation, the application of dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. The aim of this study is to introduce a new formula for calculating the centeral axis percent depth doses of Cobalt-60 beam. Materials and Methods: In the present study, based on ...
متن کاملMonte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources
Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...
متن کاملDepth dose calculation of Holmium-166 for different shape source by VARSKIN3 code
Introduction: Using beta emitter radionuclide is a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. The aim of this research is to evaluate the tissue response to beta rays of 166Ho and determine the feasibility of beta emitting radionuclide for treatment of skin cancers. Methods: In this...
متن کاملmonte carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with cobalt-60 sources
background: in the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using monte carlo (mc) method. materials and methods: two 60co sources of gzp6 brachytherapy unit used for intracavitary treatments were simulated using mcnpx monte carlo code. also the two types of colpostats including shielded and unshielded were simulated inside ...
متن کاملDose measurement of cobalt-60 radiotherapy beams in treatment fields.
BACKGROUND Radiation-therapy is a complex process with multiple steps, each of which has an impact on the quality of treatment. Accurate dosimetry is a critical step during the radiotherapy of cancer patients.The aim of the present study was to measure and evaluate the doses of two cobalt- 60 (60Co) teletherapy units GWXJ80 of NPIC China and Theratron 780 of AECL Canada at various points within...
متن کاملCalculation of depth dose profiles with a track structure code
A prerequisite for applying high-LET radiation like protons or carbon ions to patients is the precise knowledge of absorbed dose, specifically the depth dose distribution. The legal restraints imposed by the authorities requires the Bragg peak position to be reproduced within 0.5 mm and the calculated absorbed dose distribution to agree within 5% (on average) with the measurements. These condit...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of medical physicsجلد ۲، شماره ۳، صفحات ۵۳-۶۰