an assessment of the doses received by children from ct examinations along with the qc parameters from a conventional ct system
نویسندگان
چکیده
introduction: in 2000, the unscear reported that ct constitutes 5% of all the medical x-ray examinations and it contributes 34% of the resultant collective dose worldwide. children are more sensitive to the ionizing radiations than adults. so, routine quality control tests are expected to be carried out periodically on the ct scanners. the aim of this research was to estimate the effective doses received by the children below two years of age from routine ct examinations carried out at an educational imaging center in tehran. it was also aimed to evaluate the quality control parameters of the mentioned ct scanner at the same time. materials and methods: in this study, the computed tomography dose index (ctdi) values were measured at the central axis of the ct gantry in air and in the standard quality control phantoms of the head and body (as recommended by the fda) using a pencil ionization chamber and lif tld pellets for a single scan. by using the measured ctdi values and the impact software, the effective doses were calculated for every routine ct examination protocol. in this study, the quality control parameters such as noise, ct number calibration, high and low contrast resolution and the flatness of the ct image were also evaluated. these parameters were also measured using standard procedures and test objects. results: the effective dose estimated in this research ranged from 2.05 to 21.45 and 2.05 to 15.7 msv for the female and male children, respectively. the measured values of the ctdi in the standard head and body phantoms were 20.6 ± 2.01 and 11.13 ± 1.04 mgy/100 mas, respectively. the high and low contrast resolution was estimated to be 0.8 mm and 1.0 mm, respectively. conclusion: the estimated values of the effective doses in this research were less than the values reported for the netherlands, the usa, germany and were comparable with the values reported in the uk. the measured ctdi values were 11% more than that of the impact. although the estimated doses are comparable with the ones from other countries, but the quality control tests indicated that the ct number was not calibrated as well as the lack of uniformity in ct numbers. an acceptable calibration of the ct scanner not only could provide high quality images, but it could also lead to a lesser patient dose hence abiding by the alara principle in radiation protection.
منابع مشابه
An assessment of the Doses Received by Children from CT Examinations Along with the QC Parameters from a Conventional CT System
Introduction: In 2000, the UNSCEAR reported that CT constitutes 5% of all the medical x-ray examinations and it contributes 34% of the resultant collective dose worldwide. Children are more sensitive to the ionizing radiations than adults. So, routine quality control tests are expected to be carried out periodically on the CT scanners. The aim of this research was to estimate the effective ...
متن کاملAssessment of Patient Dose from CT Examinations in Khorasan, Iran
Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...
متن کاملthe aesthetic dimension of howard barkers art: a frankfurtian approach to scenes from an execution and no end of blame
رابطه ی میانِ هنر و شرایطِ اجتماعیِ زایش آن همواره در طولِ تاریخ دغدغه ی ذهنی و دل مشغولیِ اساسیِ منتقدان و نیز هنرمندان بوده است. از آنجا که هنر در قفس آهنیِ زندگیِ اجتماعی محبوس است، گسترش وابستگیِ آن با نهاد ها و اصولِ اجتماعی پیرامون، صرفِ نظر از هم سو بودن و یا غیرِ هم سو بودنِ آن نهاد ها، امری اجتناب ناپذیر به نظر می رسد. با این وجود پدیدار گشتنِ چنین مباحثِ حائز اهمییتی در میان منتقدین، با ظهورِ مکتب ما...
Estimation of patient organ doses from CT examinations in Tanzania
Although the use of computed tomography (CT) in medical diagnosis delivers relatively higher radiation doses to patients than other radiological procedures, lack of optimized protocols could be an additional source of increased dose in developing countries. The aim of this study was to determine the magnitude of radiation doses received by selected radiosensitive organs of patients from CT exam...
متن کاملthe effect of traffic density on the accident externality from driving the case study of tehran
در این پژوهش به بررسی اثر افزایش ترافیک بر روی تعداد تصادفات پرداخته شده است. به این منظور 30 تقاطع در شهر تهران بطور تصادفی انتخاب گردید و تعداد تصادفات ماهیانه در این تقاطعات در طول سالهای 89-90 از سازمان کنترل ترافیک شهر تهران استخراج گردید و با استفاده از مدل داده های تابلویی و نرم افزار eviews مدل خطی و درجه دوم تخمین زده شد و در نهایت این نتیجه حاصل شد که تقاطعات پر ترافیک تر تعداد تصادفا...
15 صفحه اولfrom linguistics to literature: a linguistic approach to the study of linguistic deviations in the turkish divan of shahriar
chapter i provides an overview of structural linguistics and touches upon the saussurean dichotomies with the final goal of exploring their relevance to the stylistic studies of literature. to provide evidence for the singificance of the study, chapter ii deals with the controversial issue of linguistics and literature, and presents opposing views which, at the same time, have been central to t...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of medical physicsجلد ۲، شماره ۳، صفحات ۳۱-۴۴
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023