introduction: image distortion is one of the major problems of magnetic resonance imaging (mri) for use in 3dmri, velocity mri, fmri and radiotherapy treatment planning (rttp). it is widely known that the most obvious effect of the inhomogenity of the magnetic fields and the nonlinearity of the gradient is the geometric distortion of mr tomograms. in this study, the accuracy of mr images was considered by the phantom study and the reproducibility of images was evaluated by repeating the phantom measurements. materials and methods: mri scans of the phantom with grid pattern inside it were performed using head coil in two 1.5 tesla mri systems (picker vista tm hpq, usa & ge signa echo speed, usa). for the geometric distortion reproducibility evaluation the t1w, t2w and pdw se protocols were repeated three times. the geometric distortion was measured by an edge detection program in matlab. results: the geometric distortion in the peripheral area of the images tends to be generally larger than it in the central area in all images. the average displacement in picker mri was 3 pixels in the y and 1 pixel in the x direction and in ge mri it was 1 pixel in both x and y direction for 24 cm fov (pixel = 0.9 mm). discussion and conclusions: since the positional variation was within 1 to 3 pixels for the head coil, it will be possible to use this mr system in 3dmri, velocity mri, fmri and rttp. to decrease the geometric distortion the use of suitable coil and protocol are expected.
منابع مشابه
Assessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements
Introduction: Image distortion is one of the major problems of magnetic resonance imaging (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is widely known that the most obvious effect of the inhomogenity of the magnetic fields and the nonlinearity of the gradient is the Geometric Distortion of MR tomograms. In this study, the...
متن کاملassessment of the efficiency of s.p.g.c refineries using network dea
data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...
Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملAssessment of Geometric Distortion in Six Clinical Scanners Using a 3D-Printed Grid Phantom
A cost-effective regularly structured three-dimensional (3D) printed grid phantom was developed to enable the quantification of machine-related magnetic resonance (MR) distortion. This phantom contains reference features, “point-like” objects, or vertices, which resulted from the intersection of mesh edges in 3D space. 3D distortions maps were computed by comparing the locations of correspondin...
متن کاملthe role of application of dynamic assessment approach in improvement of iranian efl writing performance at different language proficiency levels
the present study sought to investigate the role of dynamic assessment (da) in improvement of iranian efl writing performance at different language proficiency levels. to this end, after conducting the quick placement test, 60 iranian efl learners were assigned to two groups with different language proficiency levels. in both groups each participant wrote two compositions, one before and one af...
منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of medical physicsجلد ۲، شماره ۳، صفحات ۱-۸
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023