determination of average glandular dose in mammography for rh-rh mammogram using sobol-wu parameters in fortran code
نویسندگان
چکیده
introduction: to write a computational program to calculate the average glandular dose in mammography with rh-rh target-filter and also use it as an accurate and fast method of dose calculation founder different situations. materials and methods: in this research, the sobol-wu parameters are used to write a fortran code for glandular dose calculation in rh-rh target-filter mammograms. the code calculates the glandular dose for rh-rh target-filter mammograms for the input parameters such as tube voltage in kv scale, half-value layer (hvl) of the incident x-ray spectrum in mm al, breast thickness in cm and glandular tissue fraction (g). results: the average glandular dose variation has been calculated against the voltage of mammogram x-ray tube for d = 5 cm, hvl = 0.35 mm al and different value of g. also the results related to the average glandular absorbed dose variation per unit roentgen against the glandular fraction of breast tissue for kv=28, hvl = 0.387 mm al and different value of d are presented. discussion and conclusion: the results of this research are in good agreement with the computational results of j. m. boone and the experimental results of e. l. gingold et al. also the code is fast, accurate and user friendly, that can be used for dose optimization in mammography imaging.
منابع مشابه
Determination of Average Glandular Dose in Mammography for Rh-Rh Mammogram Using Sobol-Wu Parameters in FORTRAN Code
Introduction: To write a computational program to calculate the average glandular dose in Mammography with Rh-Rh target-filter and also use it as an accurate and fast method of dose calculation founder different situations. Materials and Methods: In this research, the Sobol-Wu parameters are used to write a FORTRAN code for glandular dose calculation in Rh-Rh target-filter mammograms. The code ...
متن کاملCalculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography
Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...
متن کاملنتایج یک کُد فرترن برای محاسبه دوز غدهای در ماموگرافی با استفاده از پارامترهای Sobol-Wu
Background: Accurate computation of the radiation dose to the breast is essential to mammography. Various the thicknesses of breast, the composition of the breast tissue and other variables affect the optimal breast dose. Furthermore, the glandular fraction, which refers to the composition of the breasts, as partitioned between radiation-sensitive glandular tissue and the adipose tissue, also h...
متن کاملEstimating average glandular dose in routine mammography screening using neural network
Given the extensive use of common mammography tests for screening and diagnosis of breast cancer, there are concerns over the increased dose absorbed by the patient due to the sensitivity of the breast tissue. Thus, knowing the Mean Glandular Dose (MGD) before radiation to the patient through its estimation can be helpful. For this reason, the MultiLayer Perceptron (MLP) neural network model wa...
متن کاملcalculation of absorbed glandular dose using a fortran program based on monte carlo x-ray spectra in mammography
introduction: average glandular dose calculation in mammography with mo-rh target-filter and dose calculation for different situations is accurate and fast. material and methods: in this research, first of all, x-ray spectra of a mo target bombarded by a 28 kev electron beam with and without a rh filter were calculated using the mcnp code. then, we used the sobol-wu parameters to write a fortra...
متن کاملAverage Glandular Dose and Entrance Surface Dose in Mammography
In general, dose evaluation for mammography uses average glandular dose (AGD). In mammography, entrance surface dose (ESD) is high, which is well known, but actual clinical data of ESD are not reported so much. This study investigated AGD and ESD for patients whose doses were estimated from 200 mammography examinations using European Organization for Quality-Assured Breast Screening and Diagnos...