an investigation of brightness changes in ultrasound images due to temperature variations in liver tissue during radiofrequency ablation
نویسندگان
چکیده
introduction: one of the minimally invasive methods of treatmenting liver malignancies is radiofrequency ablation (rfa) which can be applied to primary or secondary tumors. nevertheless, the disease recurrence is probable after rfa application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. the goal of this work was to study the possibility of real-time temperature monitoring of liver tissue undergoing rfa. for this purpose, variations of brightness in dicom ultrasonic images were investigated. materials and methods: 10pieces of fresh bovine liver underwent rfa in ex vivo experiments. active and passive needle electrodes were inserted into the tissue and a micro-thermometer was placed between them using ultrasonography guidance to invasively monitor temperature changes. corresponding to each degree of temperature up to 70 ˚c, ultrasonic images were acquired followed by turning the rf generator off and taking the images down to 30 ˚c. ultrasonic images were delivered to a pc via pacs and processed in order to investigate the subsequent changes of brightness corresponding to temperature changes. correlation analysis was performed between the changes of brightness and temperature variations with a 95% confidence level. results: this study showed that during tissue warm-up between 20 ˚c and 50 ˚c, tissue brightness of the ultrasound images increases linearly (r = 0.99). as temperature rises between 50 ˚ and 70 ˚c, the variation of brightness shows a non-linear behavior due to microbubble formation. during the cool-down process, the brightness once again behaves linearly (r = 0.98) and the variation rate of brightness is faster in the cool-down than that of the warm-up. so that at the end of rfa, when the temperature reaches the initial level the tissue is approximately 60% more hypoechoic. the results are the same for both frequencies employed. discussion and conclusion: it seems that the changes of brightness in the ultrasound images can be used for real-time thermal monitoring during radiofrequency ablation.
منابع مشابه
An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation
Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...
متن کاملRelative brightness due to temperature changes with ultrasound image analysis during Radiofrequency ablation
Introduction: Diagnosis of primary and secondary cancers to treat patients with diffuse and malignant tumors is an important subject. The appropriate treatment will be eliminating primary and metastatic tumors. Radiofrequency ablation with localized heat induction in the target tissue causes irreversible cellular damage and tissue coagulation. Estimation of tissue temperature c...
متن کاملCorrection to: Efficacy of Radiofrequency Ablation in Patients with Metastatic Liver Tumors from Breast Carcinoma
In the article published in Volume 27, issue 158, 2017, the Results section in English Abstract have been published incorrectly. The correct Results is given below: Results: The most frequent sizes of mass were 2-4 cm (n=33, 54%) and 4-5 cm (n=23, 38%). Among the patients, 35 (67.3%) had one tumor before, in 11.5% renew tumor happened, and 65.4% had one tumor after treatment. Liver tum...
متن کاملVariations in the sky brightness during a lunar eclipse
A total lunar eclipse is conjectured to have influence on the physical conditions of an environmental area, particularly on the brightness of the sky. The phenomenon might also be relevant on weather parameters change on Earth, such as temperature, humidity and pressure, though a straightforward correlation is not easy to establish. This work mainly aims at measuring the brightness of the sky a...
متن کاملInvestigation of radiofrequency ablation process in liver tissue by finite element modeling and experiment.
BACKGROUND The character of ablation processes with high-frequency electrical current is similar in most biological tissues; however, quantitative characteristics are very different. Consequently, mathematical models of the process have a lot of specific aspects. In this study, we developed mathematical model of radiofrequency ablation in liver tissues with experimental validation of model in e...
متن کاملan investigation of accuracy and complexity across different proficiency levels in written narrative task
abstract this quasi-experimental study was aimed at examining the impact of storyline complexity on the grammatical accuracy and complexity of advanced and intermediate efl learners. a total of 65 advanced and intermediate efl learners were selected from iran language institute (ili). an intact group including 35 intermediate participants and another intact group with 30 advanced participants ...