preconcentration of cu(ii)with magnetic nanocomposite sorbentsprior to determination by flame atomic absorption spectrometer

نویسندگان
چکیده

a simple, highly sensitive, accurate and selective method for determination of trace amounts of cu2+ in water samples .in this paper, chitosan was used to encapsulate nano-fe3o4 and produce a nano-fe3o4-chitosan sorbent based new sorbent was prepared. this was treated with ethylenediamine (ed) in another solvent-free procedure for the formation of a novel nano-fe3o4-chitosan-ed.flame atomic absorption spectrometer was utilized for determination of cu(ii). the analytical features for sorption were found to be 5.2; 4.3 ml min-1 and 55.0 ml for ph, flow rate and sample volume, respectively. hno3 was used as eluent and maximum preconcentration factor was found to be 200.elution parameters were also determined as 4 ml min-1; 0.6 mol l-1 and 5.1 ml forflow rate, eluent concentration and eluent volume, respectively.limit of detection and limit of quantification were found to be 49.6 and 163.7 ng l-1, respectively. validation of the developed method was performed using certified reference material (tmda-53.3). the methodology was applied for determination of cu(ii) in natural water samples and satisfactory results were obtained.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preconcentration of Cu(II)with magnetic nanocomposite sorbentsprior to determination by Flame Atomic Absorption Spectrometer

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cu2+ in water samples .In this paper, Chitosan was used to encapsulate nano-Fe3O4 and produce a nano-Fe3O4-CHITOSAN sorbent based new sorbent was prepared. This was treated with ethylenediamine (ED) in another solvent-free procedure for the formation of a novel nano-Fe3O4-Chitosan-ED.Flame atomic abs...

متن کامل

Preconcentration of Cu(II)with magnetic nanocomposite sorbentsprior to determination by Flame Atomic Absorption Spectrometer

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cu2+ in water samples .In this paper, Chitosan was used to encapsulate nano-Fe3O4 and produce a nano-Fe3O4-CHITOSAN sorbent based new sorbent was prepared. This was treated with ethylenediamine (ED) in another solvent-free procedure for the formation of a novel nano-Fe3O4-Chitosan-ED.Flame atomic abs...

متن کامل

Determination of Rhodium(III) Ions by Flame Atomic Absorption Spectrometry after Preconcentration with Modified Magnetic Activated Carbon

A new method for analysis of trace amount of Rh(III) ions by magnetic activated carbon modified with 2,3,5,6-tetra(2-pyridyl)pyrazine (MAC/TPPZ) as the magnetic sorbent has been proposed. The proposed adsorbent was found to be advantageous over conventional solid phase extraction (SPE) in terms of operational simplicity and low time-consuming. The experimental parameters affecting the extractio...

متن کامل

Preconcentration and determination of palladium water samples by ionic liquid - dispersive liquid liquid microextraction combined with flame atomic absorption spectrometry

A simple, rapid and efficient dispersive liquid–liquid microextraction by use of ionic liquid (IL-DLLME)method, followed by flame atomic absorption spectrometry (FAAS) was developed for the preconcentrationand determination of palladium in water samples. In this method, an appropriate mixture of acetone and octylmethyl imidazolium hexafluorophosphate was injected rapidly into the aqueous sample...

متن کامل

Determination of Cadmium by Flame-Atomic Absorption Spectrometry After Preconcentration on Silica Gel Modified with Cupferron

Este trabalho descreve um método para a pré-concentração de cádmio com sílica gel modificada com cupferron e sua determinação por espectrometria de absorção atômica com chama. O efeito do pH, a quantidade do material adsorvente, a concentração de eluente, volume da amostra e quantidade do analito adsorvido foram otimizados. O efeito de interferentes foi avaliado para diversos íons mostrando que...

متن کامل

determination of rhodium(iii) ions by flame atomic absorption spectrometry after preconcentration with modified magnetic activated carbon

a new method for analysis of trace amount of rh(iii) ions by magnetic activated carbon modified with 2,3,5,6-tetra(2-pyridyl)pyrazine (mac/tppz) as the magnetic sorbent has been proposed. the proposed adsorbent was found to be advantageous over conventional solid phase extraction (spe) in terms of operational simplicity and low time-consuming. the experimental parameters affecting the extractio...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of bio-inorganic hybrid nanomaterials

جلد ۵، شماره ۲، صفحات ۱۲۹-۱۳۹

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023