unexpected collection of pulmonary venous blood from a pulmonary artery catheter: a case report
نویسندگان
چکیده
conclusions our case highlights the fact that the tip of the pulmonary artery catheter can easily advance into a peripheral branch of the pulmonary artery and cause pulmonary venous blood to be sampled instead of pulmonary arterial blood. a variety of monitoring techniques are needed to confirm accurate catheter placement. background pressure and waveform at the catheter tip are continuously monitored during catheterization of pulmonary artery to ensure accurate catheter placement. we present a case in which pulmonary venous blood was unexpectedly collected from the pulmonary artery catheter despite pulmonary artery pressure and waveform detection at the catheter tip, and describe the measures taken to correct the catheter placement. case presentation a 74-year-old male underwent mitral valve plasty for cardiac failure caused by mitral valve regurgitation. preoperative transthoracic echocardiography showed no septal shunt. the pulmonary artery was catheterized through a sheath introducer in the right jugular vein, and the balloon was inflated after insertion of a 15-cm catheter. the catheter was advanced until a pulmonary artery waveform was detected and the pulmonary artery wedge pressure was 21 mmhg at end-expiration. the balloon was deflated and the catheter tip was pulled back 3 cm. pulmonary artery waveforms and appropriate a and v waves were detected, and transesophageal echocardiography confirmed the location of the catheter tip in the right pulmonary artery. the first collected blood sample had an oxygen partial pressure of 358.8 mmhg, carbon dioxide partial pressure of 20.1 mmhg, and oxygen saturation of 99%, indicating pulmonary venous blood. the pulmonary artery catheter was pulled back 5 cm, but a second blood sample showed the same results. the catheter was pulled back a further 6 cm while the location of the catheter tip was monitored on x-ray fluoroscopy. blood gas testing through the catheter tip showed oxygen saturation of 84.4 % and oxygen partial pressure of 41.6 mmhg. surgery was performed uneventfully. postoperative chest radiographs showed proper placement of the pulmonary artery catheter, but radiographs on postoperative day 1 showed over-insertion, although the insertion length was unchanged. the catheter was removed. the patient was discharged 2 months postoperatively.
منابع مشابه
Unexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report
BACKGROUND Pressure and waveform at the catheter tip are continuously monitored during catheterization of pulmonary artery to ensure accurate catheter placement. We present a case in which pulmonary venous blood was unexpectedly collected from the pulmonary artery catheter despite pulmonary artery pressure and waveform detection at the catheter tip, and describe the measures taken to correct th...
متن کاملA Case Report of Pulmonary Alveolar Microlithiasis
Pulmonary alveolar microlithiasis is a rare autosomal recessive disease characterized by the formation of calcium phosphate deposition in the alveoli. Although the disease most often occurs in children, most patients with the disease are diagnosed in adulthood due to the slow progression of the disease inside the lungs. In childhood, it often causes no symptoms, and changes in the lung parenchy...
متن کاملPulmonary Embolism as a Complication after radiofrequency catheter ablation Study: A Case Report
Pulmonary thromboembolism (PTE) is a fatal condition that may rarely occur due to complications of coronary catheter insertion. In this case report, a 41-year-old male was presented 48 hours after radiofrequency catheter ablation(RFCA) for the management of Wolf-Parkinson-White syndromewith acute onset of dyspnea, hemoptysis, and chest pain. The physical examination revealed coarse crackles in ...
متن کاملPulmonary Alveolar Microlithiasis: A Rare Case Report
Pulmonary alveolar microlithiasis is an uncommon infiltrative pulmonary disease characterized by deposition of microliths in the alveoli. We present the case of a young adult with complaints of shortness of breath on exertion. Chest radiograph showed innumerable small, dense nodules, diffusely involving both the lungs - predominantly in the lower zones. High-resolution CT scan illustrated wides...
متن کاملPrimary Pulmonary Vein Leiomyosarcoma: A Case Report
Primary leiomyosarcoma of the heart is extremely rare and found in about 0.2% of all cardiac tumors. Here in a 26-year-old man with progressive dyspnea, which had started since 2 months ago, is presented. Echocardiography revealed a left atrial mass, which was suggestive for a atrial myxoma.On the surgery, a tumoral tissue in the left atrium and pulmonary veins with attachment to peripheral sof...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
anesthesiology and pain medicineجلد ۶، شماره ۶، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023