comparing the effect of adaptive support ventilation (asv) and synchronized intermittent mandatory ventilation (simv) on respiratory parameters in neurosurgical icu patients

نویسندگان

mohammadreza ghodrati anesthesia department, firoozgar hospital, iran university of medical sciences, tehran, iran

alireza pournajafian anesthesia department, firoozgar hospital, iran university of medical sciences, tehran, iran; firoozgar hospital, iran university of medical sciences, tehran, iran. tel: +98-2188946762, fax: +98-2188942622

ali khatibi anesthesia department, firoozgar hospital, iran university of medical sciences, tehran, iran

mohammad niakan anesthesia department, rasoul akram hospital, iran university of medical sciences, tehran, iran

چکیده

results sixty patients were involved in this study. in asv mode, values including peak airway pressure (p-peak), end-tidal carbon dioxide (etco2), tidal volume and respiratory dead space were significantly lower than simv mode. although the mean value for dynamic compliance had no significant difference in the two types of ventilation, it was better in asv mode. methods in a crossover study, patients under mechanical ventilation in neurosurgical icu were enrolled. the patients alternatively experienced two types of ventilations for 30 minutes (adaptive support ventilation and synchronized intermittent mandatory ventilation). the respiratory parameters (tidal volume, respiratory rate, airway pressure, lung compliance, end-tidal carbon dioxide, peripheral oxygenation and respiratory dead space), hemodynamic variables, every 10 minutes and arterial blood gas analysis at the end of each 30 minutes were recorded. results were compared and analyzed with spss v.19. objectives this study is conducted to compare the respiratory parameters differences in adaptive support ventilation (asv) and synchronized intermittent mandatory ventilation (simv) modes in neurosurgical icu patients. background various modes of mechanical ventilation have different effects on respiratory variables. lack of patients’ neuro-ventilatory coordination and increasing the work of breathing are major disadvantages in mechanically ventilated patients. conclusions asv mode compared with simv mode can lead to improve lung compliance and respiratory dead space.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Effect of Adaptive Support Ventilation (ASV) and Synchronized Intermittent Mandatory Ventilation (SIMV) on Respiratory Parameters in Neurosurgical ICU Patients

BACKGROUND Various modes of mechanical ventilation have different effects on respiratory variables. Lack of patients' neuro-ventilatory coordination and increasing the work of breathing are major disadvantages in mechanically ventilated patients. OBJECTIVES This study is conducted to compare the respiratory parameters differences in Adaptive support ventilation (ASV) and synchronized intermit...

متن کامل

Comparison between intermittent mandatory ventilation and synchronized intermittent mandatory ventilation with pressure support in children.

OBJECTIVE To compare intermittent mandatory ventilation (IMV) with synchronized intermittent mandatory ventilation plus pressure support (SIMV+PS) in terms of time on mechanical ventilation, duration of weaning and length of stay in a pediatric intensive care unit (PICU). METHODS This was a randomized clinical trial that enrolled children aged 28 days to 4 years who were admitted to a PICU be...

متن کامل

comparing the effects of adaptive support ventilation and synchronized intermittent mandatory ventilation on intubation duration and hospital stay after coronary artery bypass graft surgery

abstract background: different modes of mechanical ventilation are used for respiratory support after coronary artery bypass graft (cabg). this study aimed to compare the effect(s) of using adaptive support ventilation (asv) and synchronized intermittent mandatory ventilation (simv) on the length of mechanical ventilation (intubation duration) and hospital stay after coronary artery bypass graf...

متن کامل

Synchronized intermittent mandatory ventilation with and without pressure support ventilation in weaning patients with COPD from mechanical ventilation.

This prospective study compared two weaning modalities in COPD patients requiring mechanical ventilation (MV) for acute respiratory failure. Nineteen patients with COPD were studied when their precipitating illness was controlled. Although they satisfied the conventional bedside weaning criteria, they could not tolerate any reduction in the respirator rate below 10 cycles/min. At this time, pat...

متن کامل

High frequency oscillatory ventilation versus synchronized intermittent mandatory ventilation in respiratory distress syndrome.

First, out of 296 infants of respiratory distress syndrome (RDS) requiring continuous positive airway pressure (CPAP), a total of 150 infants required intubation for invasive ventilation and another 53 infants requiring intubation couldn’t be randomized due to nonavailability of designated ventilator. This means that there was a CPAP failure in 69% of the cases. Studies from India itself had sh...

متن کامل

High-frequency oscillatory ventilation versus synchronized intermittent mandatory ventilation plus pressure support in preterm infants with severe respiratory distress syndrome.

BACKGROUND Mechanical ventilation and surfactants are the standard treatment of preterm respiratory distress syndrome (RDS). The effects of the primary ventilation model on bronchopulmonary dysplasia (BPD) and long-term neurodevelopment outcomes are controversial. The purpose of this study was to compare the efficacy and safety of high-frequency oscillatory ventilation (HFOV) and synchronized i...