gamma dosimetry with glass dosimeter
نویسندگان
چکیده
the radiophotoluminescence property of some materials makes it possible to use them for dosimetry purposes. the silver activated metaphoshate glass 1 as an rpl dosimeter when exposed to x. or y radiations , forms fluorescent centers with long lived states ( metastate ). the silver ions (ag+) in unirradiated state produces vacancies when energy is supplied by irradiation the release of electrons leads to the formation of rpl centers. by stimulating the crystal by the ultra - violet light 1 without destroying the rpl centres i .an orange fluorescence is produced proportional to the absorbed dose. these glasses can also be used for long term personal radiation monitoring. one of the advantages of this type of crystals is that it has linear dose sensitivity over a long range and show no fading' the relative rpl intensity is slightly dependent on radiation energy. and completely independent on dose rate. another advantage is that the dose can be added up. by heating up the crystal the fluorescent centres can be erased. the crystal is also sensitive to neutrons. thermal neutrons are detected through (n 1 a) reactions in boron ,lithium and (n, y) reaction in silver and phosphorus. the intermediate and fast neutrons are detected through elastic : scattering in lithium anp oxygen and through (n, p) reaction in ag and phosphorus ! by covering a crystal with cadmium to supress thermcl neutrons gamma dose can be measured. cadmium attenuates low' energy (kev) gamma rays. sn has the same attenuation factor for low energy gamma rays and has very low absorption cross section for thermal neutrons. in a series of experiments around the tehran university research reactor core the following measurements , using fd - ri -. i .rpl glasses and fluoroglass dosimeter type fgd - 3b as a measuring unit , were carried out : 1) integral gamma decay measurement of fission products after 2 to 5 hours operation at high power (3mw). 2) gamma intensity measurements at the, specified distances from the edge of the core in ten (10) holders fixed. to an alluminium bar (fig 1) . ,3) the; study of heating up the crystal !(fd-ri-i) up' to 400~c. the experimental results show that the fd ~rl- 1 crystal loses about 10% of its total dose after 10 minutes being at 200°0 , about 40% at 320°0 and 100% at ,400°0 for the same heating time (fig 2). 4) the sensitivity of a fission chamber to gamma radiation from the fission fragments in the core was determined. the identical fission chamber is used for starting up the reactor. the ordinary counting system and three fdri -1 crystals , one eovered with lmm thick cadmium one covvered with lmm thick sn and third bare, were placed at the same place as the fission chamber for neutron and gamma dose measurements. from these measurements it was found that the fission chamber has a sensitivity of only o. 1% to the core gammas as compared to the fission neutrons travelled 30 cm in water.
منابع مشابه
Dosimetry of gamma chamber blood irradiator using PAGAT gel dosimeter and Monte Carlo simulations
Currently, the use of blood irradiation for inactivating pathogenic microbes in infected blood products and preventing graft-versus-host disease (GVHD) in immune suppressed patients is greater than ever before. In these systems, dose distribution and uniformity are two important concepts that should be checked. In this study, dosimetry of the gamma chamber blood irradiator model Gammacell 3000 ...
متن کاملCommercial Window Glass Tested as Possible High Dose Dosimeter. Electron and Gamma Irradiation
The use of commercial window glass as possible high dose routine dosimeter has been investigated. Glass samples have been irradiated with doses in the range of 1–50 kGy using 60Co γ source, 4 MeV and 12 MeV electron accelerators. The samples were given a post irradiation thermal treatment (150 oC for 20 min) in order to improve the post irradiation stability of the measured specific optical abs...
متن کاملReference Dosimetry and Calibration of Glass Dosimeters for Cs-137 Gamma-rays
140 This research was supported by National R&D Program through the Dongnam Inst. of Radiological & Medical Sciences funded by the Ministry of Science, ICT & Future Planning (50497-2013). Submitted August, 7, 2013, Accepted August, 20, 2013 Corresponding Author: Dong Hyeok Jeong, Research Center, Dongnam Inst. of Radiological & Medical Sciences, 40, Jwadong-gil, Jangan-eup, Gijang-gun, Busan 61...
متن کاملGamma Radiation Dosimetry Using Tellurium Dioxide
Thin films of Tellurium dioxide (TeO2) were investigated for γ-radiation dosimetry purposes. Samples were fabricated using thin film vapour deposition technique. Thin films of TeO2 were exposed to a 60Co γ-radiation source at a dose rate of 6 Gy/min at room temperature. Absorption spectra for TeO2 films were recorded and the values of the optical band gap and energies of the localized states fo...
متن کاملTartrazine Solution as Dosimeter for Gamma Radiation Measurement
In this study, Tartrazine aqueous solution was investigated as a simple low-dose dosimeter in the range of 20-500 Gy for the high ionizing radiation, gamma ray. Gradual bleaching of Tartarzine solution was observed with dose by measuring the absorbance of Tartarzine-solutions at specified wavelength, λmax = 428 nm. Tartrazine concentration (10 –4 , 5 ×10 –4 and 10 –3 M) and solution-initial pH ...