radial amniotic fluid index as a new and accurate method for measurment of amniotic fluid volume

نویسندگان

m. pourissa

s. refahi

r. pezeshky a. aghazadeh

چکیده

amniotic fluid volume (afv) is one of the important parameters in the assessment of fetal well-being. the ability of ultrasound measurements to represent the actual afv is unproven. this study was undertaken to compare correlation of conventional amniotic fluid index (afi) and radial amniotic fluid index (rafi) as a new method with actual fluid volume on phantom. as an experimental study, 10 to 100 ml of water with 5 ml intervals was injected to a rubber bladder as a uterus phantom containing a 15 week gestational age fetus. the vertical diameter was measured in largest fluid pouch at each quadrant. four diameters were summed as conventional afi. the largest radial diameter perpendicular to uterus and fetus was measured at four quadrants and were summed as rafi. databases were analyzed based on correlation and regression methods. rafi and conventional afi predicted 91.6% and 65% of variations of fluid volume, respectively (p < 0.001). in conclusion, rafi is more accurate and reliable than conventional afi in the prediction of injected fluid volume.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maternal hydration for increasing amniotic fluid volume in oligohydramnios and normal amniotic fluid volume.

BACKGROUND Oligohydramnios (reduced amniotic fluid) may be responsible for malpresentation problems, umbilical cord compression, concentration of meconium in the liquor, and difficult or failed external cephalic version. Simple maternal hydration has been suggested as a way of increasing amniotic fluid volume in order to reduce some of these problems. OBJECTIVES The objective of this review w...

متن کامل

The Comparison of Maternal Endometritis in Meconium – Stained Amniotic Fluid and Clear Amniotic Fluid

Introduction: Metritis is one of the causes of maternal morbidity and there are many risk factors for it. Because of the importance of possible association of meconium-stained amniotic fluid and maternal metritis the present study was done to determine whether meconium stained amniotic fluid (MSAF) is associated with puerperal infection. Methods: In this case-control study 150 women with MSAF a...

متن کامل

Amniotic fluid and the clinical relevance of the sonographically estimated amniotic fluid volume: oligohydramnios.

The amniotic fluid volume (AFV) is regulated by several systems, including the in-tramembranous pathway, fetal production (fetal urine and lung fluid) and uptake (fetal swallowing), and the balance of fluid movement via osmotic gradients. The normal AFV across gestation has not been clearly defined; consequently, abnormal volumes are also poorly defined. Actual AFVs can be measured by dye dilut...

متن کامل

New method for determining lecithin and sphingomyelin in amniotic fluid.

We describe a new method of complete analysis for lecithin, lysolecithin, and sphingomyelin in amniotic fluid. The analysis is based on alkaline hydrolysis of the lecithins and the enzymic hydrolysis of sphingomyelin. The choline formed in each instance is enzymically phosphorylated with [gamma-32P]ATP to yield [gamma-32P]phosphorylcholine, which is isolated by anion-exchange chromatography and...

متن کامل

Study of prognostic factors for meconium-stained amniotic fluid

Introduction: meconium is the thick, Green - Black, with a bad odor material,  that founded around the third month of pregnancy in the intestines of fetus. 8 to 15 percent of infants has the evidence of meconium stained fluid at birth. In this study the factors affecting maternal and neonatal meconium-stained amniotic fluid be examined. Methods: This study was done in the Vali-e- asr hospital ...

متن کامل

Amniotic fluid cell cultures.

In an 18-month period, 249 samples of amniotic fluid were used experimentally in attempts to enhance success in cell cultures. None ofthe experimental situations proved entirely satisfactory in this aim. Emphasis is laid on the quality ofserum used in culture. Particularly satisfactory serum should be retained for use in amniotic fluid cell cultures which are dependent on unknown growth stimula...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
acta medica iranica

جلد ۴۴، شماره ۲، صفحات ۱۰۱-۱۰۴

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023