simple and rapid gas-chromatographic method for quantitation of total and free valproic acid in human serum

نویسندگان

h. r. falahat-pisheh

t. r. neyestani m. bigdeli

چکیده

valproic acid (vpa) is one of the mostly used antiepileptic drugs that may have some side effects so, it is highly recommended to evaluate its serum concentrations. the aim of this study was to develop a simple, fast and economic method using gas-chromatography equipped with flame ionization detector (gc/fid) and vpa analysis. to do this, 200 µl of serum was mixed with an aliquot of caproic acid (200 µl, methanolic solution) as internal standard and extracted by stepwise addition of hydrochloric acid and chloroform with slight agitation between each step. after centrifugation, 1.0 µl of the bottom layer was injected into a wide-bore nonpolar capillary column. injectable samples for analysis of unbonded vpa were prepared by ultra filtration followed by solid phase extraction (spe). caproic acid and vpa were eluted after 1.5 min and 3.0 min, respectively (total gc run time about 3.2 minutes). this gc/fid method was linear over a range of 2.5-6400 µg/ml with the mean recovery of 92%. the intra- and inter-assay precision in the range of 25-100 µg/ml was 1.50-, 2.95, and 2.35- 3.22%, respectively. the simplicity of sample preparation with no derivatization, short run-time and high sensitivity sufficient to detect low concentrations of the drug makes this method suitable for research as well as routine use.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma

Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...

متن کامل

Gas-chromatographic determination of valproic acid in serum without derivatization.

Valproic acid can be determined by gas-chromatography as the free acid after its extraction (1 ) or derivatization to form methyl, butyl, or phenacyl estars (2-4), the latter methods being more complicated for routine analyses. Other procedures, such as enzyme immunoassay (Syva Co., Palo Alto, CA 94304) or fluoroimmunoassay (Miles Inc., Elkhart, IN 46515), which do not require serum extraction,...

متن کامل

An Improved GC Method for Rapid Analysis of Valproic Acid in Human Plasma Without Derivatization

        A simple, reproducible and rapid gas chromatographic method for precise determination of valproic acid (VPA) in human plasma has been developed. Total time for sample preparation and GC analysis is less than 45 min. After plasma protein precipitation, VPA was extracted into chloroform with suitable recovery. By using Stabilwax®<span styl...

متن کامل

Rapid gas chromatographic method for quantitation of ethchlorvynol ("Placidyl") in serum.

A rapid, simple, and sensitive method for quantitation of ethchlorvynol by gas Chromatography has been developed. instrument response is linear to a concentration of 200 mg/liter (2.0-mi sample of serum). Day-to-day (20 days) precision of a 15 mg/liter serum pool was 0.85 mg/liter (SD) and 5.6% (CV). For 30 samples analyzed by both the gas chromatographic method and a colorimetric method, the c...

متن کامل

Quantitative gas-chromatographic flame-ionization method for p-chlorophenoxyisobutyric acid in human serum and saliva.

We describe a gas-chromatographic method for p-chlorophenoxyisobutyric acid (I) the active metabolite of clofibrate. The drug and internal standards are separated from either serum or saliva by a double extraction procedure and converted to the corresponding butyl esters by reaction with iodobutane in a mixture of methanol and N,N-di-methylacetamide containing tetramethylammonium hydroxide. Wit...

متن کامل

&quot;a gas chromatographic method for the determination of individual free fatty acids in serum&quot;

serum fatty acids on 30 healthy lranian women were detemined by a gas chromatographic method. oleic and stearic acids were used as standards. the mean values were myristic acid 5. 7% , palmitic acid 43% , palmitoleic acid 5.3% , stearic acid 8% , oleic acid 21. 3% and linleic acid 16.4% of total fatty acid serum contents.

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
acta medica iranica

جلد ۴۵، شماره ۲، صفحات ۸۵-۹۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023