transcutaneous bilirubin measurement in preterm neonates

نویسندگان

negar sajjadian department of pediatrics, shariati hospital, tehran university of medical sciences, tehran, iran.

hamideh shajari department of pediatrics, shariati hospital, tehran university of medical sciences, tehran, iran.

zeinab saalehi department of pediatrics, shariati hospital, tehran university of medical sciences, tehran, iran.

fatemeh esphahani department of epidemiology, shariati hospital, tehran university of medical sciences, tehran, iran.

چکیده

hyperbilirubinemia is a common problem during neonatal period especially in preterm neonates. transcutaneous bilirubin measurement (tcb) by special devices had been documented as an effective tool for predicting neonatal jaundice in full term neonate, but for preterm infants the present evidences are controversial. we carried out a prospective study in shariati hospital nicu. 126 paired tcb/total serum bilirubin (tsb) measurements were obtained. tcb (on forehead and sternum) were measured using jh2-1a device for every admitted preterm infant who clinically showed jaundice and tsb measurements was obtained within 30 min of tcb. 58 (46%) were male and 68 (54%) were female. the mean gestational age was 31 week and mean birth weight was 1728 ± 60 g. 30 percent of neonates were ill. the mean value obtained by tbs was 8.8 mg/dl and for frontal tcb was 8.2mg/dl and for sternal tcb was 7.4mg/dl. there were good correlation between tbs and tcb and the maximum correlation were seen in 33-37 weeks of gestation and birth weight more than 2500 g with forehead tcb measurement. healthy preterm infants had significant correlation of tsb and tcb (r=0.56, p

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcutaneous bilirubin measurement in preterm neonates.

Hyperbilirubinemia is a common problem during neonatal period especially in preterm neonates. Transcutaneous bilirubin measurement (TcB) by special devices had been documented as an effective tool for predicting neonatal jaundice in full term neonate, but for preterm infants the present evidences are controversial. We carried out a prospective study in Shariati Hospital NICU. 126 paired TcB/tot...

متن کامل

Comparison of Transcutaneous Bilirubin Measurement With Total Serum Bilirubin Levels in Preterm Neonates Receiving Phototherapy.

OBJECTIVE To compare transcutaneous bilirubin with total serum bilirubin in preterm neonates after initiation of phototherapy. METHODS Jaundice was assessed in 30 preterm neonates with transcutaneous bilirubin and total serum bilirubin before initiation of phototherapy and at 12 hr after initiation of phototherapy. A photo-occlusive patch was applied over the sternum. RESULTS Transcutaneous...

متن کامل

Comparing transcutaneous bilirubin versus serum bilirubin measurement using spectrophotometry for jaundice screening of full-term neonates

Background: Neonatal jaundice is an almost common problem among neonates that may cause complications such as kernicterus in severe cases. Since early diagnosis and proper treatment of neonatal jaundice is vital to prevent the related complications, it is necessary to check bilirubin before discharging the neonates. There are several evaluating and diagnostic methods to measure the level of bil...

متن کامل

Transcutaneous bilirubinometry in preterm neonates.

This prospective study was conducted to evaluate the accuracy of transcutaneous bilirubinometry in preterm newborns less than 32 weeks of gestation. Serum bilirubin values measured by direct spectrophotometry were considered as standard, the range was 2.2-12.5 mg/dL. 32 jaundiced infants of less than 32 weeks of gestation without phototherapy, including 10 ELBW neonates, were enrolled. Close co...

متن کامل

Transcutaneous bilirubin nomograms in African neonates

BACKGROUND The use of transcutaneous bilirubin (TcB) as a screening tool, based on relevant population-specific nomogram, or proxy for total serum bilirubin (TSB) levels in assessing the risk of subsequent hyperbilirubinemia is supported by several clinical guidelines on the management of neonatal hyperbilirubinemia. However, while TcB has been found to significantly over-estimate TSB in neonat...

متن کامل

A Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates

Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
acta medica iranica

جلد ۵۰، شماره ۱۱، صفحات ۷۶۵-۷۷۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023