unusual foreign bone fragment in femoral open fracture

نویسندگان

hanon sadoni department of orthopedic surgery, ahvaz jundishapur university of medical sciences (ajums), ahvaz, ir iran; department of orthopedic surgery, ahvaz jundishapur university of medical sciences (ajums), ahvaz, ir iran. tel: +98-9122131206; +98-6133335935

hamidreza arti department of orthopedic surgery, ahvaz jundishapur university of medical sciences (ajums), ahvaz, ir iran

چکیده

conclusions surgical and post-surgical findings showed that this segment was not related to the patient’s femur. the foreign segment may have belonged to the other victim of this trauma. introduction femoral shaft fracture is one of the typical bone fractures due to high energy trauma and may occur as an open fracture. some foreign materials may enter the fracture site such as sand, cloth particles and so on. case presentation a 28-year-old motorcycle riding military member and his collaborator were received in the hospital because of multiple traumas due to a fall in a hollow during a surveillance mission. his collaborator died because of head trauma and multiple severe open fractures. when fixing the patients femoral fracture, a large femoral butterfly fragment was removed from the patient’s thigh as a foreign segment. the patient’s femur was fixed with a plate and screws. no femoral defect was detected during surgery or post-operative x-rays and ct scan. the removed segment was not a part of the patient’s femur.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unusual Foreign Bone Fragment in Femoral Open Fracture.

INTRODUCTION Femoral shaft fracture is one of the typical bone fractures due to high energy trauma and may occur as an open fracture. Some foreign materials may enter the fracture site such as sand, cloth particles and so on. CASE PRESENTATION A 28-year-old motorcycle riding military member and his collaborator were received in the hospital because of multiple traumas due to a fall in a hollo...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

Trabecular bone modeling and subcapital femoral fracture.

Fragility fractures, including neck of femur fractures, result from reductions in the amount, quality and architecture of bone. The aim of this study was to compare the cancellous bone structure, and static indices of bone turnover, in female patients who had sustained fragility fracture at the femoral neck, with age-matched females without fragility fracture. Bone samples were taken from the i...

متن کامل

Mechanical analysis of femoral neck fracture fixation in synthetic bone

OBJECTIVE To analyze statistically results obtained between biomechanical assays on fixation of femoral neck fracture type Pauwels III, on synthetic bone, using 7.5 mm non parallel cannulated screws and control group. METHODS Ten synthetic bones from a national brand were used. Test group: fixation of 70((o)) tilt femoral neck osteotomy was performed using three 7.5 mm non parallel cannulated...

متن کامل

Regenerate bone fracture rate following femoral lengthening in paediatric patients

PURPOSE Femoral lengthening using a circular or mono-lateral frame is a commonly used technique. Fracture at the site of the regenerate bone is a major concern especially following removal of the external fixator. This aim of this study was to assess the rate of fracture of the regenerate bone in this single surgeon series of paediatric patients and determine potential risk factors. METHODS R...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
trauma monthly

جلد ۲۱، شماره ۱، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023