performance evaluation of a full-scale abs resin manufacturing wastewater treatment plant: a case study in tabriz petrochemical complex

نویسندگان

mohammad shakerkhatibi* environmental engineering, department of environmental health engineering, tabriz university of medical sciences, tabriz, iran

mohammad mosaferi environmental health engineering, department of environmental health engineering, tabriz university of medical sciences, tabriz, iran

khaled zorufchi benis faculty of chemical engineering, sahand university of technology, tabriz, iran

zahra akbari student research committee, tabriz university of medical sciences, tabriz, iran

چکیده

background: the measurement data regarding the influent and effluent of wastewater treatment plant (wwtp) provides a general overview, demonstrating an overall performance of wwtp. nevertheless, these data do not provide the suitable operational information for the optimization of individual units involved in a wwtp. a full-scale evolution of wwtp was carried out in this study via a reconciled data. methods: a full-scale evolution of acrylonitrile, butadiene and styrene (abs) resin manufacturing wwtp was carried out. data reconciliation technique was employed to fulfil the mass conservation law and also enhance the accuracy of the flow measurements. daily average values from long-term measurements by the wwtp library along with the results of four sampling runs, were utilized for data reconciliation with further performance evaluation and characterization of wwtp. results: the full-scale evaluation, based on balanced data showed that removal efficiency based on chemical oxygen demand (cod) and biochemical oxygen demand (bod5) through the wwtp were 80% and 90%, respectively, from which only 28% of cod and 20% of bod5 removal had occurred in biological reactor. in addition, the removal efficiency of styrene and acrylonitrile, throughout the plant, was approximately 90%. estimation results employing toxchem model showed that 43% of acrylonitrile and 85% of styrene were emitted into the atmosphere above water surfaces. conclusion: it can be concluded that the volatilization of styrene and acrylonitrile is the main mechanism for their removal along with corresponded cod elimination from the wwtp.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation of a full-scale ABS resin manufacturing wastewater treatment plant: a case study in Tabriz Petrochemical Complex

 Background: The measurement data regarding the influent and effluent of wastewater treatment plant (WWTP) provides a general overview, demonstrating an overall performance of WWTP. Nevertheless, these data do not provide the suitable operational information for the optimization of individual units involved in a WWTP. A full-scale evolution of WWTP was carried out in this study via a r...

متن کامل

Evaluation of sequencing batch reactor performance for petrochemical wastewater treatment

Sequencing batch reactor (SBR) technology has found many applications in industrial wastewater treatment in recent years. The aim of this study was to determine the optimal time for a cycle of the sequencing batch reactor (SBR) and evaluate the performance of a SBR for petrochemical wastewater treatment in that cycle time. The reactor was operated with a suspended biomass configuration under ae...

متن کامل

Performance Evaluation of the Extended Aeration Activated Sludge System in the Removal of Physicochemical and Microbial Parameters of Municipal Wastewater: A Case Study of Nowshahr Wastewater Treatment Plant

Introduction: Extended aeration activated sludge system has a lower sludge production than other activated sludge processes. Due to its high hydraulic retention time (HRT), the tolerance of this process is higher than the shocks caused by increased organic loading rate. The main objective of this study is to evaluate the performance of the aeration system in removing physicochemical and mi...

متن کامل

Dairy wastewater treatment plant in removal of organic pollution: a case study in Sanandaj, Iran

Background: Wastewater produced by a dairy in Sanandaj is a major source of environmental pollution threatening the city. The dairy uses activated sludge treatment to remove organic pollution from the wastewater. The present study evaluated the performance of this process and its compliance with national requirements for chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total s...

متن کامل

Performance and microbial characteristics of biomass in a full-scale aerobic granular sludge wastewater treatment plant

By modification of the operational conditions of batch reactors, a municipal wastewater treatment plant was upgraded from activated sludge to aerobic granular sludge (AGS) technology. After upgrading, the volume of the biological reactors was reduced by 30%, but the quality of the effluent substantially improved. The concentration of biomass in the reactors increased twofold; the average biomas...

متن کامل

Calibration of a complex activated sludge model for the full-scale wastewater treatment plant

In this study, the results of the calibration of the complex activated sludge model implemented in BioWin software for the full-scale wastewater treatment plant are presented. Within the calibration of the model, sensitivity analysis of its parameters and the fractions of carbonaceous substrate were performed. In the steady-state and dynamic calibrations, a successful agreement between the meas...