biological sludge stabilization fenton and ozonation processes
نویسندگان
چکیده
aims: in biological wastewater treatment processes, a large amount of sludge is produced. stabilization of sludge is essential before disposal because of the risks to human health and environment. therefore, selecting an appropriate process for stabilization this sludge may efficiently decrease risks. the aim of this study was to examine the compound efficiency of the advanced fenton and ozonation oxidation processes in stabilization of biological sludge. instrument & methods: this experimental study was conducted on raw sludge taken from kashan university of medical sciences’ wastewater treatment plant in iran during 2014. fenton and ozonation oxidation processes were used for sludge stabilization. h2o2 and fe2+ concentration, along with their mutual interaction, were measured using repeated measures model. then the effects of ph and time reaction on reduction efficiency of volatile solids (vs) were examined. findings: the maximum removal efficiencies in fenton process at ph=3 and in ozonation process in ph=7 were obtained 85.1% and 92.9%, respectively. by increasing the reaction time from 30 to 90min, vs reduction efficiency in fenton and ozonation processes increased and then reduced after 60min. the maximum reduction efficiencies of vs were obtained at 3000mg/l h2o2 concentration, so that the optimum ratio of fe2+/h2o2 for sludge stabilization was 1000/3000mg/l with the efficiency of 91.5%. conclusion: ozonation process efficiency in stabilizing biological wastewater sludge is higher than that of fenton process.
منابع مشابه
Biological treatability processes of textile wastewaters using electrocoagulation and ozonation
This study presents biotreatment of textile wastewaters using electrocoagulation and ozone processes. Ozonation process gave better results than electrocoagulation process. For electrocoagulation, optimum working conditions were found as follows: pH, 6.5; electrode type, iron electrode; current density, 20 mA/cm2; and reaction time, 15 min. Under these circumstances, values determined for elect...
متن کاملمقایسه کارایی فرایندهای فنتون و ازن زنی با فنتوازن زنی در کاهش لجن مازاد
Background and purpose: In activated sludge process large amounts of sludge are produced. The disposal and management of this sludge remains a big challenge due to environmental, economic, social and legal factors. Thus, selecting an appropriate process that could reduce sludge would be of great help in solving this problem. The aim of present research was to determine the effects of three pr...
متن کاملPhoto-fenton, Coupled Biological-photo-fenton and Reverse Osmosis Processes for Textile Wastewater Reclamation: Feasibility of Use in Dyeing Processes
متن کامل
upgrading of the fenton and electrochemicalcombined reactor (fered-fenton) for optimumwaste-activated sludge stabilization and energy consumption
introduction activated sludge process is one of the most common methods used in wastewater treatment plants. regarding the large volume of sludge obtained from such biological wastewater treatment processes and considerable costs of its treatment and disposal, extensive research has been and is being done on novel effective methods of sludge stabilization. in previous investigations research gr...
متن کاملReduction of excess sludge production by ozonation
The literature on reduction of excess sludge production by ozonation is summarized. Two sequencing batch reactor experiments where sludge is ozonated for this purpose are performed. The purpose of these is to evaluate the prospects of using ozonation to reduce excess sludge production in two different kinds of sludge. Urban sewage sludge is used in the first, and paper mill sludge in the second...
متن کاملTreatment of waste sludge: a comparison between anodic oxidation and electro-Fenton processes.
BACKGROUND Electrochemical methods, as one of the advanced oxidation processes (AOPs), have recently been applied to remove different contaminants from water and wastewater. This study compares the performance of anodic oxidation (AO) and electro-Fenton (EF) methods on waste sludge treatment. METHODS This experimental study was performed on real sludge and the effect of operating parameters s...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
international archives of health sciencesجلد ۲، شماره ۳، صفحات ۱۱۵-۱۲۰
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com