designing and fabrication of a new radiofrequency planar microcoil for mini-nuclear magnetic resonance

نویسندگان

sayyede batoul shokouhian department of biomedical engineering, faculty of engineering, university of isfahan, isfahan, iran.

alireza karimian department of biomedical engineering, faculty of engineering, university of isfahan, isfahan, iran.

mohammad mohammad-zadeh information communication technology (ict) faculty, ict ministry, tehran, iran department of nuclear engineering, shahid beheshti university g. c., tehran, iran

hamid reza salighe-rad department of medical physics & biomedical engineering and research center for science and technology (rcstim); tehran university of medical sciences, tehran, iran.

چکیده

introduction radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. in this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (pcb). it has four rings with an internal diameter of 241 microns tuned and matched at 63.8 mhz. materials and methods to achieve the maximum signal-to- noise ratio (snr) and quality factor of the coil, its geometry was optimized based on parameters such as width (w) and thickness (h) of the copper rings, the distance between the rings, inner radius of the microcoil  (ri), and the number (n) of coil rings by using comsol, ads, and matlab software packages. results our findings indicated that the q factor and snr of the coil at resonance frequency of 63.8 mhz are 63.149 and 168.23, respectively, which are higher than the equivalent features of the pervious coils. in addition, to evaluate the function of matching and tuning circuit, reflection coefficient factor (s11) of the coil was experimentally measured to be -48 db at resonance frequency of 63.8 mhz, which is consistent with the simulated value. conclusion in this study, a new microcoil was designed and fabricated to produce images of very small samples and volumes in microliter dimensions. the results showed that this new microcoil has superior capability in imaging very small samples compared to the conventional coils applied in magnetic resonance imaging devices.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

Computational study of energetic, stability, and nuclear magnetic resonance of BN nanotube as a nanosensor

Now a day study on boron nitrid nanotubes are in considerable attetion due to their unique properties in different field of science. In this letter, after final optimization, thermodynamic properties analysis, stabilities, electronic structure and nuclear magnetic resonance parameters including σ isotropic and σ anisotropic tensors and asymmetric parameters of 15N and 11B nuclei are calculated....

متن کامل

High-resolution liquid- and solid-state nuclear magnetic resonance of nanoliter sample volumes using microcoil detectors.

The predominant means to detect nuclear magnetic resonance (NMR) is to monitor the voltage induced in a radiofrequency coil by the precessing magnetization. To address the sensitivity of NMR for mass-limited samples it is worthwhile to miniaturize this detector coil. Although making smaller coils seems a trivial step, the challenges in the design of microcoil probeheads are to get the highest p...