calculation of the x-ray spectrum of a mammography system with various voltages and different anode-filter combinations using mcnp code

نویسندگان

lida gholamkar department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran,

mahdi sadeghi medical physics department, school of medicine, iran university of medical sciences, tehran, iran

ali asghar mowlavi physics department, school of sciences, hakim sabzevari university, sabzevar, iran. ictp, associate federation scheme, medical physics field, trieste, italy.

mitra athari department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran,

چکیده

introduction one of the best methods in the diagnosis and control of breast cancer is mammography. the importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. the purpose of this article was to calculate the x-ray spectrum in a mammography system with monte carlo codes, including mcnpx and mcnp5. materials and methods the device, simulated using the mcnp code, was planmed nuance digital mammography device (planmed oy, finland), equipped with an amorphous selenium detector. different anode/filter materials, such as molybdenum-rhodium (mo-rh), molybdenum-molybdenum (mo-mo), tungsten-tin (w-sn), tungsten-silver (w-ag), tungsten-palladium (w-pd), tungsten-aluminum (w-al), tungsten-molybdenum (w-mo), molybdenum-aluminum (mo-al), tungsten-rhodium (w-rh), rhodium-aluminum (rh-al), and rhodium-rhodium (rh-rh), were simulated in this study. the voltage range of the x-ray tube was between 24 and 34 kv with a 2 kv interval. results the charts of changing photon flux versus energy were plotted for different types of anode-filter combinations. the comparison with the findings reported by others indicated acceptable consistency. also, the x-ray spectra, obtained from mcnp5 and mcnpx codes for w-ag and w-rh combinations, were compared. we compared the present results with the reported data of mcnp4c and ipem report no. 78 for mo-mo, mo-rh, and w-al combinations. conclusion the mcnpx calculation outcomes showed acceptable results in a low-energy x-ray beam range (10-35 kev). the obtained simulated spectra for different anode/filter combinations were in good conformity with the finding of previous research.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of the X-Ray Spectrum of a Mammography System with Various Voltages and Different Anode-Filter Combinations Using MCNP Code

Introduction One of the best methods in the diagnosis and control of breast cancer is mammography. The importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. The purpose of this article was to calculate the X-ray spectrum in a mammography system with Monte Carlo codes, including MCNPX and MCNP5...

متن کامل

assessment of mean glandular dose in mammography system with different anode-filter combinations using mcnp code

conclusion by comparing the results, we saw that w/rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with w/ag and rh/al. moreover, breast thickness and g value have significant effects on mgd. objectives the aim of this study was to determine the average absorbed dose of x-ray radiation in the glandular tissue of the...

متن کامل

Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code

BACKGROUND X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. OBJECTIVES The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast d...

متن کامل

X-ray spectra calculation for different target-filter of mammograms using MCNP Code

 ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...

متن کامل

x-ray spectra calculation for different target-filter of mammograms using mcnp code

abstractbackground: an electron beam generated x-ray spectrum consists of characteristic x-ray and continuous bermsstrahlung. the aim of this research is calculating and comparing x-ray spectra for different target filter of mammograms. materials and methods: monte carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the x-ray spectra. mcn...

متن کامل

X-ray spectra calculation for different target-filter of mammograms using MCNP Code

Mammography is one of the most important imaging techniques to diagnose breast cancer. It is perhaps the single most important innovation in breast cancer control. The importance of mammography is directly related to its value in the early detection and management of breast cancer. Mammography detects approximately 2-3 times as many early breast cancers as physical exams. Breast cancer is the s...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of medical physics

جلد ۱۳، شماره ۳، صفحات ۱۵۴-۱۶۲

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023