determination of methotrexate in biological fluids and a parenteral injection using terbium-sensitized method

نویسندگان

abolghasem jouyban pharmaceutical analysis laboratory, drug applied research center, tabriz university of medical sciences, tabriz, iran.

masoomeh shaghaghi department of analytical chemistry, faculty of chemistry, university of tabriz, tabriz, iran.

jamshid l. manzoori department of analytical chemistry, faculty of chemistry, university of tabriz, tabriz, iran.

jafar soleymani kimia research institute, tabriz, iran.

چکیده

a new sensitive, simple and rapid method for determination of methotrexate (mtx) was developed based on quenching effects of mtx on the fluorescence intensity of tb3+-1,10-phenanthroline complex. the fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of mtx in tris-hcl buffer solution with a ph of 7.0. the effects of ph, time, order of addition of the reagents, temperature and the concentrations of tb3+, buffer and 1,10-phenanthroline were investigated and optimized. the obtained linear range for the determination of mtx was 0.02-10 μg/ml. the detection limits (signal: noise = 3) was 0.015 μg/ml and the relative standard deviation for replicated determinations of 1 μg/ml of mtx was 1.9%. the proposed method is a simple, practical and relatively free from interference effects and was successfully applied to assess mtx in urine, serum and samples of an injection solution.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb(3+)-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in T...

متن کامل

Determination of norfloxacin using a terbium-sensitized electrogenerated chemiluminescence method.

A simple electrogenerated chemiluminescence (ECL) analysis method for the determination of norfloxacin (NFLX) is reported. It is based on ECL produced by Na(2)SO(3), which is sensitized by the Tb-NFLX complex. The relative ECL intensity of the Tb(3+)-NFLX-Na(2)SO(3) system is proportional to the amount of NFLX. The optimized experimental conditions were investigated. The linear range and detect...

متن کامل

Terbium sensitized determination of tosufloxacin using electrochemiluminescence method.

A novel method for determination of trace amounts of tosufloxacin (TFLX) based on electrochemiluminescence (ECL) has been developed. The calibration graphs for TFLX were linear in the range of 5.0 x 10(-11)-3.5 x 10(-7) mol/L, with the detection limit of 1.3 x 10(-11) mol/L. Key factors affecting the determination of TFLX were investigated. TFLX amounts in capsule and serum samples were success...

متن کامل

Development of a Simple and Sensitive Terbium Sensitized Fluorescence Method for Determination of Epinephrine and Norepinephrine in Serum

     A simple, rapid, selective and highly sensitive fluorimetric method for determination of two catecholamines, i.e. norepinephrine (NE) and epinephrine (EP), in serum samples was developed. The method is based on the fluorescence sensitization of terbium (Tb3+) by complexation with both catecholamines in the presence of lanthanum (La3+), as a co-cation, and in a Na...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of pharmaceutical research

جلد ۲۰۱۱، شماره ۴، صفحات ۶۹۵-۷۰۴

کلمات کلیدی
[ ' t e r b i u m ' , ' s e n s i t i z e d ' , 1 , 1 0 , ' p h e n a n t h r o l i n e ' , ' m e t h o t r e x a t e ' , ' i n j e c t i o n s o l u t i o n ' , ' u r i n e ' , ' s e r u m ' ]

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023