a comparison of pulmonary valve gradient measurement by doppler and catheterization

نویسندگان

حسن رنجبرنژاد اصفهانی

h ranjbar nejad

چکیده

in this study, trans-pulmonic valvular gradient of 51 patients with congenital pulmonary stenosis measured by cw-doppler and cardiac catheterization were compared to find whether they are comparable and if doppler method is accurate enough for interventional decision-making. results showed that findings in both methods were comparable and doppler method is accurate and enough for clinical decision.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a comparison of linguistic and pragmatic knowledge: a case of iranian learners of english

در این تحقیق دانش زبانشناسی و کاربردشناسی زبان آموزان ایرانی در سطح بالای متوسط مقایسه شد. 50 دانش آموز با سابقه آموزشی مشابه از شش آموزشگاه زبان مختلف در دو آزمون دانش زبانشناسی و آزمون دانش گفتار شناسی زبان انگلیسی شرکت کردند که سوالات هر دو تست توسط محقق تهیه شده بود. همچنین در این تحقیق کارایی کتابهای آموزشی زبان در فراهم آوردن درون داد کافی برای زبان آموزان ایرانی به عنوان هدف جانبی تحقیق ...

15 صفحه اول

a comparison of teachers and supervisors, with respect to teacher efficacy and reflection

supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...

15 صفحه اول

CONGENiTAL HEART DSEASE Usefulness cif the Doppler Mean Gradient in Evaluation of Children with Aortic Valve Stenosis and Comparison to Gradient at Catheterization

To assess the usefulness of the Doppler mean gradient as a noninvasive indkzator of the need for htterventien, 33 chikiren (ages 3 months to 20 years) with valvuiar aor& stenosis (AS) undement . aP=dimeWonalandDoppler~ aphic examination a median of 1 day before cardiac catheterizatkm The clinical decision for i*ention was based on finditig a catheterization peak-to-peak presurogradientof>75mmHg...

متن کامل

Pulmonary valve obstruction during cardiac catheterization.

OBSTRUCTION of a stenotic pulmonary valve by the exploring cardiac catheter, a serious and not infrequent complication of cardiac catheterization, has received little attention in the literature.1-4 Experiences in this laboratory indicate that pulmonary valve obstruction can occur both in a manifest, symptomatic form and in a concealed, asymptomatic form in patients with severe pulmonary stenos...

متن کامل

assessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks

testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...

extremal region detection guided by maxima of gradient magnitude

a problem of computer vision applications is to detect regions of interest under dif- ferent imaging conditions. the state-of-the-art maximally stable extremal regions (mser) detects affine covariant regions by applying all possible thresholds on the input image, and through three main steps including: 1) making a component tree of extremal regions’ evolution (enumeration), 2) obtaining region ...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
مجله دانشکده پزشکی دانشگاه علوم پزشکی تهران

جلد ۵۵، شماره ۵، صفحات ۳۴-۳۸

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023