design and optimization of a new voltammetric method for determination of isoniazid by using pedot modified gold electrode in pharmaceuticals

نویسندگان

fatma demirkaya-miloglu ataturk university

tuba oznuluer atatürk university

buket ozdurak ataturk university

elmas miloglu ataturk university

چکیده

isoniazid (inh) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. this composite electrode exhibited 4-fold higher oxidation of inh, in accordance with peak densities, than the bare gold electrode. it was used the central composite design method to obtain optimum experimental conditions, and used critical parameters (ph (a), scan rate (mv/s, b) and temperature (c, c) to assess the effects on amperometric response. optimum experimental conditions were achieved by using a ph of 9.2 with a scan rate of 260 mv/s and a temperature of 30c. under these conditions, a good linear relationship was observed between peak current densities and inh concentration in the range of 0.05-2 μm, with correlation coefficient of 0.9998. furthermore, the method was very sensitive (limit of quantitation, 0.0043 μm), accurate (relative error, -5.65 to 4.03) and precise (relative standard deviation %, ≤7.97). the method was also applied to determine inh in pharmaceutical formulations, and statistically compared the results with the official method using the two one-sided equivalence test; the results were in good agreement with those obtained by the official and reported methods.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals

Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central compo...

متن کامل

Design and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals

Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central compo...

متن کامل

Design and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticls

Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetric and controlled potential techniques. Electrocatalytic performance measurements of this composite electrode toward oxidation of INH exhibited an increase of 4-folds in oxidation peak densities compa...

متن کامل

voltammetric behavior and determination of isoniazid in pharmaceuticals by using silver oxyfluoride modified silver electrode

in the present study, silver oxyfluoride modified silver electrode was employed to electrocatalytic oxidation of isoniazid. the process of oxidation and its kinetics were established by using cyclic voltammetry, chronoamperometry and amperometry techniques. the modified electrode shows a stable and linear response in the concentration range of 3×10−4 to 2.1×10−3 mol l-1 with a correlation coeff...

متن کامل

solution of security constrained unit commitment problem by a new multi-objective optimization method

چکیده-پخش بار بهینه به عنوان یکی از ابزار زیر بنایی برای تحلیل سیستم های قدرت پیچیده ،برای مدت طولانی مورد بررسی قرار گرفته است.پخش بار بهینه توابع هدف یک سیستم قدرت از جمله تابع هزینه سوخت ،آلودگی ،تلفات را بهینه می کند،و هم زمان قیود سیستم قدرت را نیز برآورده می کند.در کلی ترین حالتopf یک مساله بهینه سازی غیر خطی ،غیر محدب،مقیاس بزرگ،و ایستا می باشد که می تواند شامل متغیرهای کنترلی پیوسته و گ...

Voltammetric microsensor using PEDOT-modified gold electrode for the simultaneous assay of ascorbic and uric acids

A voltammetric microsensor has been developed for the simultaneous assay of ascorbic (AA) and uric (UA) acids in aqueous solution. Theelectrode surface hasbeenmodifiedbymeansof electropolymerized conductive poly(3,4-ethylenedioxythiophene) PEDOT organic films. The electrocatalytic activity of the interface was dependent on the electropolymerization parameters inducing change in the structure an...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of pharmaceutical research

جلد ۱۵، شماره Special Issue، صفحات ۶۵-۷۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023