the comparison of microscopic method and rapid diagnostic test in detecting plasmodium species

نویسندگان

alireza salimi khorashad infectious diseases and tropical medicine research center, boo-ali hospital, zahedan university of medical sciences, zahedan, ir iran; infectious diseases and tropical medicine research center, boo-ali hospital, zahedan university of medical sciences, zahedan, ir iran. tel: +98-5413424393, fax: +98-5413424393

masoud salehi infectious diseases and tropical medicine research center, boo-ali hospital, zahedan university of medical sciences, zahedan, ir iran

bita roshanravan department of chemical and environmental engineering, faculty of engineering, university putra malaysia, 43400 serdang, selangor d.e., malaysia

چکیده

background since iran is one of the malaria endemic areas, diagnosis of this disease is important. although the microscopic study of stained peripheral blood smears is as a gold standard of malaria diagnosis, this method requires a microscope, the equipment, and trained people. because of some problems associated with microscopic method in some situations, rapid diagnostic test (rdts) can be a suitable alternative. nevertheless, then diagnosis of malaria should be approved by microscopic objectives the rapid diagnosis of disease and treatment of patients is necessary to identify the contributing factors and break the cycle of transmission. in order to achieve this goal, we need a method that requires no special equipment such as microscopes, paint trays, and specially trained technicians for microscopic detection method patients and methods blood sample were drawn from the finger of 178 patients with suspected malaria by a technician. two methods of microscopic detection and rdt kits with immune chromatographic procedures were employed to diagnose malaria. finally, all slides and cassettes of rdt kits were transferred to zahedan for reviewing and control. results after data collection, the results of 178 samples were reported according to the plasmodium species. rdt detected 71.4% of plasmodium vivax while microscopic method had detected all the cases (100%). although there was a significant difference between two methods of diagnosis in detecting p. vivax (p < 0.05), the results were the same in diagnosing plasmodium falciparum (100%). conclusions our study showed that only 71.4% of all positive samples for p. vivax were detected by rdt. the results were the same for both methods in diagnosis of p. falciparum.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the relationship between learners critical thinking ability and their performance in the reading sections of the tofel and ielts test

the study reflected in this thesis aims at finding out relationships between critical thinking (ct), and the reading sections of tofel and ielts tests. the study tries to find any relationships between the ct ability of students and their performance on reading tests of tofel and academic ielts. however, no research has ever been conducted to investigate the relationship between ct and the read...

15 صفحه اول

construction and validation of the translation teacher competency test and the scale of students’ perceptions of translation teachers

the major purpose of this study was to develop the translation teacher competency test (ttct) and examine its construct and predictive validity. the present study was conducted in two phases: a qualitative phase as well as a quantitative phase. in the first phase of the study, the author attempted to find out the major areas of competency required for an academic translation teacher. the second...

comparison of catalytic activity of heteropoly compounds in the synthesis of bis(indolyl)alkanes.

heteropoly acids (hpa) and their salts have advantages as catalysts which make them both economically and environmentally attractive, strong br?nsted acidity, exhibiting fast reversible multi-electron redox transformations under rather mild conditions, very high solubility in polar solvents, fairly high thermal stability in the solid states, and efficient oxidizing ability, so that they are imp...

15 صفحه اول

ParaSight-F rapid manual diagnostic test of Plasmodium falciparum infection.

The ParaSight(R)-F test is a qualitative diagnostic test of Plasmodium falciparum, which is based on the detection by a monoclonal antibody of a species-specific soluble antigen (histidine-rich protein (HRP-II)) in whole blood and which can be performed without special equipment. A visual reading is given by a polyclonal antibody coupled with dye-loaded liposomes; when positive, a pink line app...

متن کامل

Detecting Malaria Hotspots: A Comparison of Rapid Diagnostic Test, Microscopy, and Polymerase Chain Reaction

Background Malaria control strategies need to respond to geographical hotspots of transmission. Detection of hotspots depends on the sensitivity of the diagnostic tool used. Methods We conducted cross-sectional surveys in 3 sites within Kilifi County, Kenya, that had variable transmission intensities. Rapid diagnostic test (RDT), microscopy, and polymerase chain reaction (PCR) were used to de...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of infection

جلد ۱، شماره ۳، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023