determination of amoxycyllin and clavulanic acid in pharmaceutical dosage forms by hplc with amperometric detection

نویسندگان
چکیده

a simple and sensitive high performance liquid chromatographic method with electrochemical detection is described for the quantitative determination of the amoxycillin and clavulanic acid in pharmaceutical dosage forms. separation of sample components occurs on a reversed phase c18 column with a mobile phase consisting of methanol-water-phosphate buffer. for the amperometric detection, the potentials of +1.180 and +1.250 v were set on the working electrode for amoxycillin and clavulanic acid, respectively. high linearity over a concentration range of (25 ng to 250 ng, r = 0.998) and (31.25 ng to 1 µg, r = 0.999) was observed. this method is convenient and reproducible for analysis of these two components in different dosage forms.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DETERMINATION OF AMOXYCYLLIN AND CLAVULANIC ACID IN PHARMACEUTICAL DOSAGE FORMS BY HPLC WITH AMPEROMETRIC DETECTION

A simple and sensitive high performance liquid chromatographic method with electrochemical detection is described for the quantitative determination of the amoxycillin and clavulanic acid in pharmaceutical dosage forms. Separation of sample components occurs on a reversed phase C18 column with a mobile phase consisting of methanol-water-phosphate buffer. For the amperometric detection, the pote...

متن کامل

Determination of Amoxycyllin and Clavulanic Acid in Pharmaceutical Dosage Forms by Hplc with Amperometric Detection

A simple and sensitive high performance liquid chromatographic method with electrochemical detection is described for the quantitative determination of the amoxycillin and clavulanic acid in pharmaceutical dosage forms. Separation of sample components occurs on a reversed phase C18 column with a mobile phase consisting of methanol-water-phosphate buffer. For the amperometric detection, the pote...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

RP-HPLC method development and validation for determination of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms

A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 colum...

متن کامل

Simultaneous Determination of Metformin and Pioglitazone by Reversed Phase Hplc in Pharmaceutical Dosage Forms

A simple, sensitive and rapid reverse phase high performance liquid chromatographic method was developed for the estimation of Metformin Hcl (MET) and Pioglitazone (PIO) in pure and in pharmaceutical dosage forms. A Gemini C18 column (150x4.6mm, 5μ) was used with a mobile phase containing a mixture of Acetonitrile and Ammonium Acetate buffer (pH-3) in the ratio of 42: 58. The flow rate was 0.3m...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of sciences islamic republic of iran

جلد ۱۲، شماره ۲، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023