spectrophotometric simultaneous kinetic determination of iodide and iodate using partial least-squares calibration method in a single kinetic run

نویسندگان
چکیده

a rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (pls) using original and derivate data named as absorbance and rate data. the method is based on the catalytic effect of the cited anions on the reaction rate between ce(iv) and as(iii) in 2 mol l?1 sulfuric acid medium. the savitzky-golay convolution method is used for calculating and smoothing the rate data. results show that pls is an excellent calibration method to resolve the mixtures of two anions by first-order or pseudo first-order kinetic procedures without any previous knowledge about rate constant values. the 26 calibration solutions were made of iodide and iodate in the range of 10-48 and 55-235 ng ml?1. the rmsep calculated for 12 test solutions are 0.1756, 0.5074 and 0.2327, 0.9197 for the absorbance and rate data for iodide and iodate respectively. the application of the method was confirmed by analysis of these anions in real matrix samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run

A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...

متن کامل

Kinetic spectrophotometric determination of certain cephalosporins using iodate/iodide mixture

A simple, precise and accurate kinetic spectrophotometric method for determination of cefradine anhydrous, cefaclor monohydrate, cefadroxil monohydrate, cefalexin anhydrous and cefixime in bulk and in pharmaceutical formulations has been developed. The method based on a kinetic investigation of the reaction of the free carboxylic acid group of the drug with a mixture of potassium iodate and pot...

متن کامل

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares

A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...

متن کامل

simultaneous spectrophotometric determination of iron, cobalt and copper by partial least-squares calibration method in micellar medium

iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. the organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. the ability of micel...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of sciences islamic republic of iran

جلد ۱۷، شماره ۱، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023