fluence map optimization in intensity modulated radiation therapy for fuzzy target dose

نویسندگان

alireza fakharzadeh jahromi

omolbanin bozorg

hamidreza maleki

mohamad amin mosleh-shirazi

چکیده

although many methods exist for intensity modulated radiotherapy (imrt) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. in this paper, the best fluence maps for an imrt procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. first, a defuzzyingprocedure was introduced to change the fuzzy model of the problem into an equivalent non-fuzzy one. since the solution set was nonconvex, the optimal solution was then obtained by performing a projection operation in applying the gradient method. numerical simulations for two typical clinical cases (for prostate and head-and-neck cancers, each for two patients) are given.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FLUENCE MAP OPTIMIZATION IN INTENSITY MODULATED RADIATION THERAPY FOR FUZZY TARGET DOSE

Although many methods exist for intensity modulated radiotherapy (IMRT) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. In this paper, the best fluence maps for an IMRT procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. First, a d...

متن کامل

Iterative Solution Methods for Beam Angle and Fluence Map Optimization in Intensity Modulated Radiation Therapy Planning

We present computational approaches for optimizing beam angles and fluence maps in Intensity Modulated Radiation Therapy (IMRT) planning. We assume that the number of angles to be used for the treatment is given by the treatment planner. A mixed integer programming (MIP) model and a linear programming (LP) model are used to find an optimal set of beam angles and their corresponding fluence maps...

متن کامل

RICE UNIVERSITY A Sensitivity-Driven Greedy Approach to Fluence Map Optimization in Intensity-Modulated Radiation Therapy by

A Sensitivity-Driven Greedy Approach to Fluence Map Optimization in Intensity-Modulated Radiation Therapy

متن کامل

A method for standardizing intensity modulated radiation therapy planning optimization for nasopharyngeal carcinoma

Background: To investigate a method for standardizing intensity modulated radiation therapy (IMRT) optimization for nasopharyngeal carcinoma (NPC), in order to reduce the influence of subjective factors. Materials and Methods: This study is based on example IMRT plans for NPC, which were randomly divided into data acquisition and data verification groups. Organs at risk (OARs) were analyzed for...

متن کامل

Intensity‐modulated radiation therapy dose verification using fluence and portal imaging device

Patient-specific quality assurance for intensity-modulated radiation therapy (IMRT) dose verification is essential. The aim of this study is to provide a new method based on the relative error distribution by comparing the fluence map from the treatment planning system (TPS) and the incident fluence deconvolved from the electronic portal imaging device (EPID) images. This method is validated fo...

متن کامل

Direct Aperture Optimization for Intensity Modulated Radiation Therapy: Two Calibrated Metaheuristics and Liver Cancer Case Study

Integrated treatment planning for cancer patients has high importance in intensity modulated radiation therapy (IMRT). Direct aperture optimization (DAO) is one of the prominent approaches used in recent years to attain this goal. Considering a set of beam directions, DAO is an integrated approach to optimize the intensity and leaf position of apertures in each direction. In this paper, first, ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of fuzzy systems

ناشر: university of sistan and baluchestan

ISSN 1735-0654

دوره 8

شماره 4 2011

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023