electropolymerization of 4-aminobenzoic acid containing nano-au deposited on carbon paste electrode for determination of acetaminophen
نویسندگان
چکیده
the conducting polymer films have been widely applied in the field of electrochemistry owing to their goodstability, permselectivity, unique physical and chemical properties. a novel nano-au/poly (4-aminobenzoicacid) (paba) film modified carbon paste electrode was fabricated for sensitive detection of acetaminophenin this paper. the paba film and nano-au/paba film were characterized by scanning electron microscope.the nano-au/paba film exhibited obviously catalytic performance to the determination of acetaminophenwith a high sensitivity and a wide linear range. under optimum conditions (ph, the concentration of 4-aminobenzoic acid, electro-polymerization cycles), linearity between the oxidation peak current and theacetaminophen concentration was obtained in the range of 1.0 × 10–7 – 8.0 × 10–5 mol l-1 with a detectionlimit of 8.0 × 10–8 mol l-1 (s/n = 3). in addition, the nano-au/paba film modified electrode wassuccessfully employed to determine the acetaminophen in commercial drugs, and this work has shed somedoubt on the redox mechanism of acetaminophen at the sensor.
منابع مشابه
Electropolymerization of 4-aminobenzoic acid containing nano-Au deposited on carbon paste electrode for determination of acetaminophen
The conducting polymer films have been widely applied in the field of electrochemistry owing to their goodstability, permselectivity, unique physical and chemical properties. A novel nano-Au/poly (4-aminobenzoicacid) (PABA) film modified carbon paste electrode was fabricated for sensitive detection of acetaminophenin this paper. The PABA film and nano-Au/PABA film were characterized by scanning...
متن کاملElectropolymerization of Glycine at Carbon Paste Electrode and its Application for the Determination of Methyl Orange
A recently constructed polyglycine modified carbon paste electrode (PGMCPE) was employed to evaluate the electrochemical behavior of methyl orange (MO). The developed electrode was characterized by FESEM to understand the morphology of the modified electrode and bare carbon paste electrode (BCPE). The modified electrode exhibits an excellent electrochemical activity towards the oxidation of MO....
متن کاملapplication and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples
ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...
15 صفحه اولSynergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen
Monitoring the acetaminophen in biological samples and also in pharmaceutical formulations is important due to the concerns of public health care and drug safety. In this work a carbon paste electrode modified with BaTiO3 nanoparticle (BTO NPs) and room-temperature ionic liquid (IL) (n-hexyl-3-methylimidazolium hexafluoro phosphate) was fabricated. The direct electro-oxidation behavior of aceta...
متن کاملCOBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID
A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...
متن کاملElectrochemical Sensor for Determination of Ascorbic Acid Using a 2-Chlorobenzoyl Ferrocene/Carbon Nanotube Paste Electrode
A chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2CBF) and carbon nanotube (2CBFCNPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. The diffusion coefficient (D = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of the iranian chemical researchجلد ۵، شماره ۳، صفحات ۱۶۱-۱۷۱
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023