simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares
نویسندگان
چکیده
a partial least squares (pls) calibration model was developed for the simultaneous spectrophotometricdetermination of pb (ιι), cu (ιι) and ni (ιι) using xylenol orange as a chromogenic reagent. the parameterscontrolling behavior of the system were investigated and optimum conditions were selected. the calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead, copper and nickel,respectively. the experimental calibration matrix was designed with 21 mixtures of these chemicals.absorbance data were taken between 350-650 nm and absorbance data were autoscaled. a set of syntheticsample mixtures were used to validate the proposed method. the root mean square errors of predictions(rmseps) and percent of relative prediction errors (rseps) are 0.2164, 0.0744, 0.0735 ppm and ±7.1855, ±6.3193, ± 7.0806% for lead, copper and nickel, respectively.
منابع مشابه
Simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares
A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...
متن کاملSpectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares
A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...
متن کاملmultiwavelength pectrophotometric determination of stability constants of 4-(2– thiazolylazo) resorcinol (tar) with la3+, y3+ and th4+ in organic-water mixed solvents by chemometrics method & simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares calibration method
تشکیل کمپلکس های tarبا یون های لانتانیم, ایتریم و توریم در دمای 25 درجه، قدرت یونی ثابت 0.1 مولار و در ph ثابت در مخلوط حلال های اتانول – آب و استونیتریل – آب با استفاده از روش های اسپکتروفوتومتری مورد بحث و بررسی قرار گرفت. داده های اسپکتروفوتومتری با استفاده از نرم افزار squad پردازش شدند تا ثابت های تشکیل کمپلکس اندیکاتور – فلز را محاسبه کند. نتایج نشان می دهد که درصد حلال آلی در مخلوط حلال ...
15 صفحه اولspectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares
a method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-thiazolylazo)-p-cresol (tac) in micellar media of triton x-100 isproposed. the absorbance spectra were recorded in the range of 500 to 800 nm. the linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...
متن کاملSpectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares
A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on the formation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 is proposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentration range for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.1...
متن کاملSimultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium
Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of the iranian chemical researchجلد ۵، شماره ۴، صفحات ۲۱۳-۲۲۱
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023