the ever increasing rate of power consumption has led to an increase in public exposure to extremely low frequency magnetic fields (elf-mfs) and brought severe concerns about their health effects. considering previous studies and the facts about potential health effects of these fields, the present study aimed to evaluate the elf-mf flux densities from power distribution lines near hospitals in tehran. elf-mf measurements were performed according to ieee standard procedures-std 644-1994 near the hospitals entrances using hi-3604 power frequency field strength measurement system during three different time periods (i.e. 12-3 am, 9-12 am, 6-9 pm). the results were analyzed using one-way anova test. mean, minimum, and maximum values of elf-mf flux densities were 0.165 ± 0.08 μt, 0.018 μt, 0.52 μt, respectively. there were no statistically significant differences in elf-mf flux densities neither among different hospital groups nor among different time periods. the elf-mf flux densities from power distribution lines around tehran hospitals were much less than the standards values, implying that it can be considered only in epidemiological studies. in fact, in the case of powerful sources, magnetic field intensity is declined rapidly by distance and is limited to a few meters around the sources. this subject is considered as one of the main reasons for contradictory results in previous studies. results of the present study can be used as a part of hospital patients’ exposure to quantify the total exposure levels of patients as a critical and sensitive group in tehran hospitals.
منابع مشابه
extremely low frequency magnetic flux densities measured near hospital in tehran
the ever increasing rate of power consumption has led to an increase in public exposure to extremely low frequency magnetic fields (elf-mfs) and brought severe concerns about their health effects. considering previous studies and the facts about potential health effects of these fields, the present study aimed to evaluate the elf-mf flux densities from power distribution lines near hospitals in...
متن کاملInvestigation of Extremely Low Frequency Magnetic Field (ELF-MF) Flux Densities in the Vicinity of Schools in Tehran
Epidemiologic studies have shown the relation between exposure to extremely low frequency magnetic fields (ELF-MFs) and childhood leukemia, so assessment of children exposure levels in different environments is considered as a serious precedence. Present study aimed at determining ELF-MFs flux densities near schools in Tehran. Measurements were performed near randomly selected schools in three ...
متن کاملOccupational exposure of dentists to extremely-low-frequency magnetic field.
OBJECTIVE To compare occupational exposure to extremely-low-frequency magnetic field (ELF-MF) between dentists practicing in dental clinics and those employed in hospitals. METHODS Thirty-two dentists who worked at clinics (n=15) and 33 dentists employed at hospital dental departments (n=7) voluntarily provided their informed consent to participate in this measurement study. The study dentist...
متن کاملExposure of school employees to extremely low frequency magnetic fields.
This study was initiated to determine and compare daily occupational exposure (OE) and non-occupational exposure (NOE) of three employee groups of teachers, maintenance workers and secretarial staff in a Canadian school district. The time-weighted average (TWA) individual OE for subjects ranged from 0.4-3.8 milligauss (mG), and the TWA NOE ranged from 0.2-7.1 mG. TWA OE and NOE were 1.2 mG and ...
متن کاملExtremely low-frequency magnetic fields and health effects: literature review
Este estudo foi financiado pela ANEEL – Agência Nacional de Energia Elétrica. Colaboradores: I. M. e M. H. realizaram a busca bibliográfica e revisão da literatura, escreveram e revisaram o manuscrito. N. G. coordenou o trabalho e revisou o manuscrito. Correspondência: Izabel Marcilio. Faculdade de Medicina da Universidade de São Paulo. Av. Dr. Arnaldo, 455 São Paulo, SP CEP 01246-903. E-mail: ...
متن کاملExtremely Low Frequency Magnetic Field Modulates the Level of Neurotransmitters
This study was aimed to observe that extremely low frequency magnetic field (ELF-MF) may be relevant to changes of major neurotransmitters in rat brain. After the exposure to ELF-MF (60 Hz, 2.0 mT) for 2 or 5 days, we measured the levels of biogenic amines and their metabolites, amino acid neurotransmitters and nitric oxide (NO) in the cortex, striatum, thalamus, cerebellum and hippocampus. The...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
international journal of environmental researchناشر: university of tehran