removal of copper ions from contaminated soil by enhanced soil washing
نویسندگان
چکیده
this study investigated the feasibility of using different extracting solutions at various concentrations to remove copper from low permeability silty loam soils, which have a high buffering soil, ph of 7.6, where it spiked with copper at concentration of about 1500 mg/kg to represent soil conditions. the most efficient extracting solutions could be used as purging/extracting solutions in other technologies such as soil washing. several batch tests were conducted to be optimizing the various parameters like stirring speed, mixing time, surfactant-chelating agent concentration, and the liquid/solid ratio (l/s). the following extracting solutions were investigated for the removal of copper from the soils: distilled water, chelating agents (edta ethylenediaminetetraacetic acid), and surfactant (sds, sodium dodecyl sulphate). the metal removal efficiency was found to be dependent on edta concentration at case used alone, with the increasing of edta concentration, the removal of cu+2 increased and peaking at approximately 42.4% with increasing of edta concentration to 0.1m. the addition of 0.6% sds retarded copper removal by edta, therefor, the removal become approximately 32 %, as compared when edta was applied alone.
منابع مشابه
Remediation of Nitrobenzene Contaminated Soil by Combining Surfactant Enhanced Soil Washing and Effluent Oxidation with Persulfate
The combination of surfactant enhanced soil washing and degradation of nitrobenzene (NB) in effluent with persulfate was investigated to remediate NB contaminated soil. Aqueous solution of sodium dodecylbenzenesulfonate (SDBS, 24.0 mmol L-1) was used at a given mass ratio of solution to soil (20:1) to extract NB contaminated soil (47.3 mg kg-1), resulting in NB desorption removal efficient of 7...
متن کاملSimultaneous Removal of Cadmium and Turbidity in Contaminated Soil-washing Water by Electroflotation
The removal of cadmium and turbidity from contaminated soil-washing water was studied by Electroflotation (EF) at the laboratory scale by using sodium lauryl sulfate (SLS) as an anionic surfactant, and calcium hydroxide (Ca(OH)2) as a coagulant. The stoichiometric cadmium to collector (SLS) and coagulant (Ca(OH)2) ratio was 1:4.5. Significant removal of cadmium (100 %, not detected in the resid...
متن کاملCadmium removal from contaminated soil by tunable biopolymers.
An elastin-like polypeptide (ELP) composed of a polyhistidine tail (ELPH12) was exploited as a tunable, metal-binding biopolymer with high affinity toward cadmium. By taking advantage of the property of ELPH12 to undergo a reversible thermal precipitation, easy recovery of the sequestered cadmium from contaminated water was demonstrated as the result of a simple temperature change. In this stud...
متن کاملCopper phytoavailability and uptake by Elsholtzia splendens from contaminated soil as affected by soil amendments.
Pot and field experiments were conducted to evaluate bioavailability of Cu in contaminated paddy soil (PS) and phytoremediation potential by Elsholtzia splendens as affected by soil amendments. The results from pot experiment showed that organic manure (M) applied to the PS not only remarkably raised the H2O exchangeable Cu, which were mainly due to the increased exchangeable and organic fracti...
متن کاملImproved removal of Trinitrotoluene (TNT) from contaminated soil by inducing aerobic process: kinetic and chemical byproducts
This study describes the biological degradation of TNT by using induced aeration. Three plastic reactors were used. In each reactor 3 kg of soil were used. In order to increase the porosity of the soil, sawdust was added to soil. Textile wastewater treatment plant sludge was also added to soil. TNT at the concentrations of 1000 mg/kg of soil was added thereafter. Rhamnolipid biosurfactant at th...
متن کاملBiodegradation of Polychlorinated Biphenyls by and Isolated from Contaminated Soil
Polychlorinated biphenyls (PCBs) cause many significant ecological problems because of their low degradability, high harmfulness, and solid bioaccumulation.Two bacterial strains were isolated from soil that had been polluted with electrical transformer liquid for more than 40 years. The isolates were distinguished as Lysinibacillus macrolides DSM54Tand Bacillus firmus NBRC1530...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
international journal of environmental researchناشر: university of tehran
ISSN 1735-6865
دوره 9
شماره 4 2015
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023