evaluation of horizontal - flow roughing filteration performance in turbidity removal

نویسندگان

دکتر علی ترابیان

مهندس عبدالله رشیدی مهر آبادی

چکیده

slow sand filtration (s.s.f) is a main process in the water treatment technology and generally considered as most appropriate for application in rural and small urban areas in developing countries. however, performance of the s.s.f is very sensitive to high turbidity levels. therefore, pretreatment is necessary for such waters. horizontal - flow roughing filtration (hfrf) and direct horizontal - flow roughing filtration (dhrf) have been porposed as two effective pre-treatment technologeis, prior to ssf. in this study two par all el lab - scale pilot plants were used. each pilot consisted of three units: raw water supply unit , coagula tion un it and horizontal filter. the filter was made of p. v. c. tubes, each 20 cm in diameter. each filter consisted of a 1.5 m long first compartment (15 to 25 mm grains) and 1.5 m second compartment (3-5 mm grains in firs t filter and 7-9 mm grains in second filter) . initial turbidity was 300 ntu. the coagulant dose in dhrf was 2.5 mg/l fecl3. the results of the experiments indicated that the efficiency of filtration decreases as the filtration rat e is increased. also, a fine graded filter, has a higher efficiency than a coarse graded one. in the first compartment of the filter in a dhrf procosses, floculation and sedimentation are efficiently achieved. the amount of wash water in the fast drain age method is acceptable. the scour velocity increases with the increased sludge age .

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the performance of conventional and baffled horizontal subsurface constructed wetland in the removal of Reactive Red 198

Background and Objective: Reactive Red 198 is a mono azo dye widely used in the textile industry of Iran. The toxicity of reactive dyes is higher than other dyes and causes disorders such as irritation, cancer and mutation in humans. The overall objective of this study was to determine the efficiency of a Constructed Wetland pilot system with conventional and baffled horizontal subsurface flow ...

متن کامل

Evaluation of Chitosan and Magnesium Oxide Nanoparticles Efficiencies in Removal of Direct Blue 71 and Turbidity

Introduction: High volumes of wastewater along with contaminants, such as colloids and dyes are discharged from different industries into the environment. These wastewaters create major problems and serious threats for water resources. Therefore, it is essential to treat such wastewaters and reach the effluent discharge standards. In this regard, chitosan as a coagulant has a comparable perform...

متن کامل

evaluation of sadr eminence in safavid period

چکیده: یکی از دوره های مهم تاریخی ایران به لحاظ تأمین استقلال ملی مذهبی و حتی تأثیر آن بر فرهنگ و مذهب ایرانیان، دوره صفویه است. رسمیت دادن و رواج مذهب شیعه توسط شاه اسماعیل اول، یکی از مهمترین اقدامات این دولت محسوب می شود. بنابراین برای اجرای این سیاست، وی منصب صدارت را به عنوان منصبی مذهبی- حکو متی ایجاد کرد .این منصب از دوره ی تیموریان ایجاد شده بود ولی در اواخر این دوره اهمیت بیشتری یافت...

15 صفحه اول

"investigation of roughing filter efficiency on turbidity and parasite egg removal from raw water"

slow sand filters are as a proper technology for pre-treatment of raw water, with a fine and medium trubidity in small communities in developing countries. thus, with a minimum operation cost and minimum need for expest bodies have the maximum efficiency. the purpose of this research is carried out to evaluate the efficiency of two processes of horizontal flow roughing filter and vertical flow ...

متن کامل

Initial contaminant removal performance factors in horizontal flow reed beds used for treating urban wastewater.

This study evaluates the effect of hydraulic loading rate (HLR), aspect ratio, granular medium size and water depth on the removal of selected contaminants during the start up of horizontal subsurface flow reed beds (HFRBs). Experiments were carried out in a pilot-scale HFRB system comprising four pairs of lined beds of almost equal surface area (54-56 m(2) each bed), with the following aspect ...

متن کامل

ocsillator system lucidity performance in turbidity removal abstract

background: ocsillator system is recognized by many water plant treatment designers for having many advantages, such as combination of mixing processes, flocculation and sedimentation processes in the same unit, the possibility of softening and lucidity simultaneously, and relatively acceptable efficiency. despite using this process in number of the regions in the country, enough researches hav...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
محیط شناسی

جلد ۲۵، شماره ۲۴، صفحات ۰-۰

کلمات کلیدی